Mercury Slipring Mercotac Model 335

Model 335
Three Conductors,
3@30amps & 500V

 

Mercury Slipring, Mercotac Model 335

Mercury Slipring, Mercotac Model 335


Disconnects included (6 lg.)
Boot Kit available
Available with stainless steel
  ball bearing (335-SS)
Model No.
Terminals
Voltage
AC/DC
Amp
Rating
@500VAC
Max.
Freq.
MHz
Contact
Resistance
Max.
RPM
Temp
Max. F (C) /
 Min. F (C)
Rotation
Torque (gm-cm)
Circuit
Separation
335
3
0-500
30
100

<1m

500
140 (60) /-20(-29)
700

>50M

335-SS
3
0-500
30
100

<1m

500
140 (60) /-20(-29)
700

>50M

"SS" designator indicates stainless steel ball bearing (recommended for wet or corrosive environments)

335 Accessories
Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
57335
Boot Kit for dust or splash
protection IP51
55250
Terminal 16 - 14 AWG
(qty. 3 included)
55251
Terminal 16 - 14 AWG
(qty. 3 included)
Terminals for other wire gauges available.
(22-18 AWG and 12-10 AWG)
335 Standard Wire Connections

Mercury Slipring, Mercotac Model 335

335 Wire Connections With Optional Boot
Mercury Slipring, Mercotac Model 335
  335 Suggested Mounting Methods
Model 335 is typically mounted by either the black body or the white plastic bushing on either end using a set screw.  When mounting horizontally, mount the Mercotac so the body of the connector rotates.

Typical Body Mount Hole Dimensions

MODEL HOLE DIAMETER () * DEPTH
335, et al 1.575"    (40.0) .80"    (20.3)

Typical Bushing Mount Hole Dimensions

335, et al .984"    (25.0) .80"    (20.3)
*Inch  (mm) Tolerance    +.001" (+.025)
    -.000" (-.000)

Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
Mercury Slipring, Mercotac Model 335
Installation Notes:
  • the up arrow should not point below horizontal
  • do not solder to or bend connector tabs
  • avoid lateral forces and mechanical loads (overly stiff or tight wires)
  • do not rigid mount both ends of connector
  • limit mounting eccentricity (runout / wobble) to .005" (.13mm)
  • provide overload protection within the circuit
  • avoid vibration and bumping motions

Back Top Top