AC Input Module/Alarm/Transmitter

 AC Input Alarm
 AC Input Transmitter
  Hot-Swappable Plug-In Design
  Looptracker® LED
s
  Push to Test
  Lifetime Warranty
Model Input Output Ranges Features Data & Applications Photo
API 2000 Series
DuoPak®

Two Channel Isolated Transmitter

Specify Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Strain Gauge
See data sheet for input specifications and model numbers
Specify Output Range for Each Channel
Factory Configured
0-1 V,
0-5 V,
1-5 V,
0-10 V
±5 V,
±10 V
0-1 mA,
0-20 mA,
4-20 mA
Others available
Two Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC, 48-300 VDC Power
API 20xx DD for 9-30 VDC,
10-32 VAC Power (+$60)
Data Sheet

Reference Info
Alarm Terminology
Deadband

RFI / EMI
Relay Protection & EMI Suppression

Application Examples
Motor Current Monitor & Overcurrent Shutdown
Monitor & Display AC Motor Load
Monitoring Motor Speed Using Current

Heater Break Alarm
Monitor Computer & Process Status
API 1600 G
AC Input Single Alarm Trip
Specify Input, Alarm Type & Power


API 1620 G
AC Input Dual Alarm Trip
Specify Input, Alarm Type & Power

Factory Configured
Minimum: 50mVAC
Maximum: 600VAC
Minimum: 1mAAC
Maximum: 1AAC
1 or 2 Field
Adjustable
7A SPDT
Alarm Relays
Hot- Swappable Plug-In Design
Looptracker® LEDs for Input
Alarm Status LEDs
Push to Test/Reset
Uses 11-Pin Socket

Data Sheet

Applications

Heater Break Alarm

Reference Info

Alarm TerminologyDeadband
Relay Protection & EMI Suppression




APD 6380

Field Selectable Minuteman Setup

AC to DC Transmitter
Isolated


Hundreds of Field Configurable
Input Ranges
0-40 mVAC to
0-300 VAC
0-4 mAAC to
0-200 mAAC

APD 6380 Ranges

18 Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
Others available

Minuteman One-Minute Setup
Removable Plugs
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Selectable Sink/Source
20 V Output Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC, 10-32 VAC Power
Data Sheet

Reference Info
Alarm Terminology
Deadband

RFI / EMI
Relay Protection & EMI Suppression

Application Examples
Motor Current Monitor & Overcurrent Shutdown
Monitor & Display AC Motor Load
Monitoring Motor Speed Using Current

Heater Break Alarm
Monitor Computer & Process Status

Removable Plugs!


API 6010 G
Isolated AC to DC Transmitter
Specify Input, Output & Power
Factory Configured
Minimum: 50mVAC
Maximum: 100VAC
Minimum: 1mAAC
Maximum: 5AAC
Factory Configured
Others available
0-1V
0-5V
1-5V
0-10V
5V
10V
0-20mA
4-20mA
Hot- Swappable Plug-In Design
Looptracker® LEDs for Input and Output
Full Isolation
Push to Test
Uses 8-Pin Socket
Data Sheet

Reference Info

RFI / EMI



API 6010 G 5A
Isolated AC to DC Transmitter
Specify Input, Output & Power
Factory Configured
0-1AAC
0-2AAC
0-3AAC
0-5AAC
0-10AAC
Factory Configured
Others available
0-1V
0-5V
1-5V
0-10V
5V
10V
0-20mA
4-20mA
Hot- Swappable Plug-In Design
Looptracker® LEDs for Input and Output
Full Isolation
Push to Test
Includes 8-Pin Socket with
Shunt Resistor
Data Sheet

Applications

Motor Current Monitor & Overcurrent Shutdown
Monitor & Display AC Motor Load
Monitoring Motor Speed Using Current

Reference Info

RFI / EMI



API 6010 G 20A
Isolated AC to DC Transmitter
Specify Input, Output & Power
Factory Configured
Others available
0-5AAC
0-10AAC
0-15AAC
0-20AAC
Factory Configured
Others available
0-1V
0-5V
1-5V
0-10V
5V
10V
0-20mA
4-20mA
Hot- Swappable Plug-In Design
Looptracker® LEDs for Input and Output
Full Isolation
Push to Test
Includes 8-Pin Socket with
Shunt Resistor
Data Sheet

Applications

Motor Current Monitor & Overcurrent Shutdown
Monitor & Display AC Motor Load
Monitoring Motor Speed Using Current

Reference Info

RFI / EMI



API 6380 G
Field Selectable
Isolated AC to DC Transmitter
Specify Power




API 6380 G HV
True Field Selectable
Minuteman Setup


AC to DC Transmitter
Isolated, High Voltage Input
API 6380 G
20 Field Configurable Input Ranges
0-50 mVAC to
0-250 VAC
0-5 mAAC to
0-200 mAAC
For >200mAAC to 5 Amps use Socket/Shunt Resistor API-008-5A


API 6380 G HV

24 Field Configurable Input Ranges
Same as API 6380 but with 0 to 300 VAC, 0-400 VAC, 0-500 VAC, 0-600 VAC input ranges in addition to standard ranges
API 6380 G
16 Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA

API 6380 G HV
16 Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
s
Minuteman One-Minute Setup
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Uses API-008 8-Pin Socket
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60)
Data Sheet

Range Settings

Help Sheet

Reference Info

RFI / EMI



API 6380 G S
Field Selectable
Isolated AC True RMS to DC Transmitter
Specify Power




API 6380 G SHV
Field Selectable
Minuteman Setup


True RMS AC to DC
Transmitter Isolated,
High Voltage Input

API 6380 G S
20 Field Configurable Input Ranges
0-50 mVAC to
0-250 VAC
0-5 mAAC to
0-200 mAAC
For >200mAAC to 5 Amps use Socket/Shunt Resistor API-008-5A


API 6380 G SHV

24 Field Configurable Input Ranges
Same as API 6380 but with 0 to 300 VAC, 0-400 VAC, 0-500 VAC, 0-600 VAC input ranges in addition to standard ranges
API 6380 G S
16 Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA

API 6380 G SHV
16 Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
s
Minuteman Setup
Hot- Swappable Plug-In Design
Looptracker® LEDs for Input & Output
Push to Test
Full Isolation
Uses 8-Pin Socket
For 1 Amp to 5 Amps use Socket/Shunt Resistor API-008-5A
For 5 Amps to 20 Amp use Socket/Shunt Resistor API-008-20A
Data Sheet

Range Settings

Help Sheet

Reference Info