| SINEAX Multi-Function Power Meters & Transducers
|
|
A210 & A220 Multifunction Power Meters |
| Measurement of current, voltage, active, reactive and apparent power, active and reactive energy, neutral conductor current, power factor and frequency
|
 
EMMOD
|
|
Input:
| Single or 3-Phase, 0-1 A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz |
| Output:
| Programmable Digital Pulse Relay |
- A210 1/4 DIN size or A220 Full-Size DIN
- 19 Types of Measurements Including
- P, Q, S, I~, U~ (rms), cos φ, (PF, 4 quadrants), f, Pint, Qint, Sint
- 3 Variable Display
- Open Collector Alarm Relay and Pulse Outputs
- Data Logging and MODBUS with EMMOD 201 Option
- Two Analog Outputs with EMMOD 202 Option
- Ethernet Interface with EMMOD 203 Option
- PROFIBUS Interface with EMMOD 204 Option
- Hi/Lo Electrical Rates
- Includes RS-232 Measurement & Configuration Software
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions EMMOD MODBUS
|
|
A230 & A230s Multifunction Power Meter w. System Load & Harmonics |
| Measurement of current, voltage, active, reactive and apparent power, active and reactive energy, neutral conductor current, power factor and frequency
|
 
EMMOD
|
|
Input:
| Single or 3-Phase, 0-1 A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz |
| Output:
| Programmable Digital Pulse Relay |
- A230 Full-Size DIN or A230s 1/4 DIN
- 19 Types of Measurements Including
- P, Q, S, I~, U~ (rms), cos φ (PF, 4 quadrants), f, Pint, Qint, Sint, THD, harmonics, UNE, unbU
- Three 4-digit Programmable Displays
- Open Collector Alarm Relay and Pulse Outputs
- Data Logging and MODBUS with EMMOD 201 Option
- Two Analog Outputs with EMMOD 202 Option
- Ethernet Interface with EMMOD 203 Option
- PROFIBUS Interface with EMMOD 204 Option
- Hi/Lo Electrical Rates
- Comprehensive mean and max./min. value functions with trend
- System analysis functions (THD, harmonics, asymmetry)
- Includes RS-232 Measurement & Configuration Software
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions EMMOD MODBUS
|
|
A2000 True RMS Multifunction Power Meter |
|
Input:
| Single or 3-Phase, 0-1A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz |
Output:
| Programmable
4 Analog
2 Digital Pulse
2 Relays | 
|
- Display 4 Variables
- Up to 4 Analog and 2 Pulse Outputs
- Data Logging of any of 37 Values
- 2 Relay Outputs
- Alarm Contacts Triggered on any Setpoint
- Includes Measurement & Configuration Software
- MODBUS / LONBUS / PROFIBUS Versions
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions
|
|
M 563 Power & Current Transducer |
|
Input:
| 0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz |
Output:
| 0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V |
|
- 3 Analog Outputs
- Measures any Three: P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF, QF, f
- RS 232 PC Programming Interface
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions
|
|
Sineax CAM Multifunction Energy Transducer |
|
Input:
| 0-1A, 0-5 A or
Two 4-20 mA
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Digital I/O |
Output:
| RS-485 MODBUS interface
USB 2.0
Relay
Up to 4 analog
Digital I/O |


|
- True RMS
- Simultaneous measurement of all 3 phases
- Measures P, Q or S, I ~, U ~ (RMS), cos f, sin f, LF, PF, QF, LF, f, THD, TDD, VAR
- USB programming interface
- 85-265 VAC/ 110-265 VDC powered
- Optional 17-90 VDC powered
|
 CAM Specifications CAM Instructions
MODBUS Instructions
|
|
Sineax A200 Multifunction Display for DME Power Transducers |
|
Input:
| Serial data from DME4 series |
Output:
| 3 digital displays |


|
- 1/4 DIN (96 x 96 mm) display for DME4 transducers
- Triple LED display 14 mm digit height
- Selectable display parameters
- 20-265 VAC/VDC powered
|
 A200 Specifications A200 Instructions
|
|
Sineax DME 401 Energy Transducer with MODBUS Interface |
|
Input:
| 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz |
Output:
| RS-485 MODBUS interface |
 
|
- RS-485 MODBUS interface
- Measures P, Q or S, I ~, U ~ (RMS), cos f, sin f, LF, PF, QF, f
- Data logging function
- RS 232 PC programming interface
- 24-60 VAC/VDC or 85-230 VAC/VDC powered
|
|
 DME 401 Specifications DME 401 Instructions
MODBUS Instructions MODBUS Basics
|
|
Sineax DME 440 Energy Transducer w. MODBUS & 4 Analog Outputs |
|
Input:
| 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz |
Output:
| RS-485 MODBUS interface
4 analog outputs:
0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V |
 
|
- RS-485 MODBUS interface
- 4 analog outputs
- Measures P, Q or S, I ~, U ~ (RMS), cos f, sin f, LF, PF, QF, f
- Data logging function
- RS 232 PC programming interface
- 24-60 VAC/VDC or 85-230 VAC/VDC powered
|
 DME 440 Specifications DMR 440 Instructions
|
|
DME 424 & DME 442 Energy Transducers |
|
Input:
| 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz |
Output:
| 0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
Open Collector Pulse |
|
- DME 424 with 2 analog and 4 digital pulse outputs
- DME 442 with 4 analog and 2 digital pulse outputs
- Measures P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF, QF, f
- Data Logging Function
- RS 232 PC Programming Interface
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions
|
|
DME 406 Energy Transducer |
|
Input:
| 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz |
Output:
| Profibus DP |
|
- Measures P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF, QF, f
- Data Logging Function
- RS 232 PC Programming Interface
- RS485 with Profibus DP output
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered

|
 Specifications Instructions
|
|
P 530 Active Power & Q 531 Reactive Power Transducers |
|
Input:
| 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
100-690 V
50/60 Hz |
Output:
| 0-1 mA to 0-20mA
1-5 mA to 4-20 mA
1 mA to 20 mA
0-1 V to 2-10 V, to 10 V |


|
- 3-Phase with Balanced or Unbalanced Load
- Sinusoidal Input
- Available as Measuring Source Powered to 230 V
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions
|
|
Sineax M 561 Power & Current Transducer |
|
Input:
| 0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz |
Output:
| One analog output
0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V |


|
- 1 analog output
- Measures any One: P, Q or S, I ~, U ~ (RMS), cos f, sin f, LF, PF, QF, f
- RS 232 PC programming interface
- 24-60 VAC/VDC or 85-230 VAC/VDC powered
|
 M 560 Series Specifications M 560 Series Instructions
|
|
Sineax M 562 Power & Current Transducer |
|
Input:
| 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
100-690 V
50/60 Hz |
Output:
| 2 analog outputs
0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V |


|
- 2 analog outputs
- Measures any two: P, Q or S, I ~, U ~ (RMS), cos f, sin f, LF, PF, QF, f
- RS 232 PC programming interface
- 24-60 VAC/VDC or 85-230 VAC/VDC powered
|

M 560 Series Specifications M 560 Series Instructions
|
|
Sineax M 563 Power & Current Transducer |
|
Input:
| 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
100-690 V
50/60 Hz |
Output:
| 3 analog outputs
0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V |

|
- 3 analog outputs
- Measures any Three: P, Q or S, I ~, U ~ (RMS), cos f, sin f, LF, PF, QF, f
- RS 232 PC programming interface
- 24-60 VAC/VDC or 85-230 VAC/VDC powered
|

M 560 Series Specifications M 560 Series Instructions
|
| SINEAX Current Transducers
|
| SINEAX Voltage Transducers
|
|
U 539 AC Voltage Transducer |
|
Input:
| 0-50 V to 0-600 V
50/60 Hz |
Output:
| 0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V |
 
|
- Sinusoidal Input
Available as Measuring Source Powered to 230 V
24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions
|
|
U 543 AC Voltage Transducer |
|
Input:
| 0-20 V to 0-600 V
50/60 Hz |
Output:
| 0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V |

|
|
|
 Specifications Instructions
|
|
U 553 True RMS AC Voltage Transducer |
|
Input:
| 0-20 V to 0-690 V
50/60 or 400 Hz |
Output:
| 0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V |

|
- Sine, Rectangular or Distorted Wave Forms
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions
|
|
U 554 True RMS AC Voltage Transducer |
|
Input:
| 0-20 V to 0-690 V
50/60 or 400 Hz |
Output:
| 0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V |


|
|
|
 Specifications Instructions
|
| SINEAX Frequency Transducers
|
|
F 534 Frequency Transducer |
|
Input:
| 10 V to 690 V
10 to 1500 Hz |
Output:
| 0-1 mA to 0-20mA
1-5 mA to 4-20 mA
1 mA to 20 mA
0-1 V to 2-10 V, to 10 V |


|
- Sine, Rectangular or Distorted Wave Forms
- Available as Measuring Source Powered to 230 V
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions
|
|
F 535 Frequency Difference Transducer |
|
Input:
| 10 V to 690 V
10 to 1500 Hz |
Output:
| 0-1 mA to 0-20mA
1-5 mA to 4-20 mA
1 mA to 20 mA
0-1 V to 2-10 V, to 10 V |

|
- Measure Δf Between 2 Synchronized Supplies
- Sine, Rectangular or Distorted Wave Forms
- Available as Measuring Source Powered to 230 V
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions
|
| SINEAX Phase Angle (Power Factor) Transducers
|
|
G 536 Phase Angle Transducer |
|
Input:
| 1 or 5 A
10 V to 690 V
16 to 400 Hz
0.5 cap. 1.ind. 0.5 cos Φ |
Output:
| 0-1 mA to 0-20mA
1-5 mA to 4-20 mA
1 mA to 20 mA
0-1 V to 2-10 V, to 10 V |

|
- Measure Single or 3-Phase Balanced
- Sine, Rectangular or Distorted Wave Forms
- Available as Measuring Source Powered to 230 V
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|
 Specifications Instructions
|
|
G 537 Phase Angle Difference Transducer |
|
Input:
| 10 V to 690 V
50 or 60 Hz |
Output:
| 0-1 mA to 0-20mA
1-5 mA to 4-20 mA
1 mA to 20 mA
0-1 V to 2-10 V, to 10 V |


|
- Measure ΔΦ Between 2 Synchronized Supplies
- Sine, Rectangular or Distorted Wave Forms
- Available as Measuring Source Powered to 230 V
- 24-60 VAC/VDC or 85-230 VAC/VDC Powered
|