Camille Bauer SINEAX Electrical Power Measurement

Camille Bauer SINEAX multifunctional heavy-current transducers are programmable and may be used for the measurement of almost all quantities of an electrical power system. The application (system configuration) as well as the behaviour of the analog and digital outputs are software configurable. The measurand acquisition via programming or bus interface during normal operation is also supported.

SINEAX Multi-Function Power Meters & Transducers SINEAX Power Transducers
SINEAX Current Transducers SINEAX Voltage Transducers
SINEAX Phase Angle (Power Factor) Transducers SINEAX Frequency Transducers

SINEAX Multi-Function Power Meters & Transducers

A210 & A220 Multifunction Power Meters

Measurement of current, voltage, active, reactive and apparent power, active and reactive energy, neutral conductor current, power factor and frequency
EMMOD

Input:

Single or 3-Phase, 0-1 A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz
Output: Programmable Digital Pulse Relay
  • A210 1/4 DIN size or A220 Full-Size DIN
  • 19 Types of Measurements Including
  • P, Q, S, I~, U~ (rms), cos φ, (PF, 4 quadrants), f, Pint, Qint, Sint
  • 3 Variable Display
  • Open Collector Alarm Relay and Pulse Outputs
  • Data Logging and MODBUS with EMMOD 201 Option
  • Two Analog Outputs with EMMOD 202 Option
  • Ethernet Interface with EMMOD 203 Option
  • PROFIBUS Interface with EMMOD 204 Option
  • Hi/Lo Electrical Rates
  • Includes RS-232 Measurement & Configuration Software
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications   Instructions  EMMOD  MODBUS

A230 & A230s Multifunction Power Meter w. System Load & Harmonics

Measurement of current, voltage, active, reactive and apparent power, active and reactive energy, neutral conductor current, power factor and frequency
EMMOD

Input:

Single or 3-Phase, 0-1 A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz
Output: Programmable Digital Pulse Relay
  • A230 Full-Size DIN or A230s 1/4 DIN
  • 19 Types of Measurements Including
  • P, Q, S, I~, U~ (rms), cos φ (PF, 4 quadrants), f, Pint, Qint, Sint, THD, harmonics, UNE, unbU
  • Three 4-digit Programmable Displays
  • Open Collector Alarm Relay and Pulse Outputs
  • Data Logging and MODBUS with EMMOD 201 Option
  • Two Analog Outputs with EMMOD 202 Option
  • Ethernet Interface with EMMOD 203 Option
  • PROFIBUS Interface with EMMOD 204 Option
  • Hi/Lo Electrical Rates
  • Comprehensive mean and max./min. value functions with trend
  • System analysis functions (THD, harmonics, asymmetry)
  • Includes RS-232 Measurement & Configuration Software
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications   Instructions  EMMOD  MODBUS

A2000 True RMS Multifunction Power Meter

Input:

Single or 3-Phase, 0-1A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz

Output:

Programmable
4  Analog
2  Digital Pulse
2  Relays
  • Display 4 Variables
  • Up to 4 Analog and 2 Pulse Outputs
  • Data Logging of any of 37 Values
  • 2 Relay Outputs
  • Alarm Contacts Triggered on any Setpoint
  • Includes Measurement & Configuration Software
  • MODBUS / LONBUS / PROFIBUS Versions
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

M 563 Power & Current Transducer

Input:

0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz

Output:

0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V

  • 3 Analog Outputs
  • Measures any Three: P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF, QF, f
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

DME 424 & DME 442 Energy Transducers

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz

Output:

0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
Open Collector Pulse

  • DME 424 with 2 analog and 4 digital pulse outputs

  • DME 442 with 4 analog and 2 digital pulse outputs

  • Measures P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF, QF, f
  • Data Logging Function
  • RS 232 PC Programming Interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

DME 406 Energy Transducer

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz

Output:

Profibus DP

  • Measures P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, PF, QF, f
  • Data Logging Function
  • RS 232 PC Programming Interface
  • RS485 with Profibus DP output
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

SINEAX Power Transducers

P 530 Active Power & Q 531 Reactive Power Transducers

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
100-690 V
50/60 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
1 mA to 20 mA
0-1 V to 2-10 V, to 10 V

  • 3-Phase with Balanced or Unbalanced Load

  • Sinusoidal Input

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

SINEAX Current Transducers

I 538 AC Current Transducer

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 Hz

Output:

0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
  • Sinusoidal Input

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications   Instructions

I 542 AC Current Transmitter

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 Hz

Output:

0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
  • Sinusoidal Input

  • Powered from Measuring Source

Specifications   Instructions

I 552 True RMS AC Current Transducer

Input:

0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 or 400 Hz

Output:

0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
  • Sine, Rectangular or Distorted Wave Forms

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

SINEAX Voltage Transducers

U 543 AC Voltage Transducer

Input:

0-20 V to 0-600 V
50/60 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

  • Sinusoidal Input

  • Powered from Measuring Source

Specifications  Instructions

U 553 True RMS AC Voltage Transducer

Input:

0-20 V to 0-690 V
50/60 or 400 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

  • Sine, Rectangular or Distorted Wave Forms

  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

U 554 True RMS AC Voltage Transducer

Input:

0-20 V to 0-690 V
50/60 or 400 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

  • Sine, Rectangular or Distorted Wave Forms

  • Special Version to Allow Zero Offset

  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

SINEAX Frequency Transducers

F 534  Frequency Transducer

Input:

10 V to 690 V
10 to 1500 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
1 mA to 20 mA
0-1 V to 2-10 V, to 10 V

  • Sine, Rectangular or Distorted Wave Forms

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

F 535 Frequency Difference Transducer

Input:

10 V to 690 V
10  to 1500 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
1 mA to 20 mA
0-1 V to 2-10 V, to 10 V

  • Measure Δf Between 2 Synchronized Supplies
  • Sine, Rectangular or Distorted Wave Forms

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

SINEAX Phase Angle (Power Factor) Transducers

G 536 Phase Angle Transducer

Input:

1 or 5 A
10 V to 690 V
16 to 400 Hz
0.5 cap. 1.ind. 0.5 cos Φ

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
1 mA to 20 mA
0-1 V to 2-10 V, to 10 V

  • Measure Single or 3-Phase Balanced
  • Sine, Rectangular or Distorted Wave Forms

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions

G 537 Phase Angle Difference Transducer

Input:

10 V to 690 V
50 or 60 Hz

Output:

0-1 mA to 0-20mA
1-5 mA to 4-20 mA
1 mA to 20 mA
0-1 V to 2-10 V, to 10 V

  • Measure ΔΦ Between 2 Synchronized Supplies
  • Sine, Rectangular or Distorted Wave Forms

  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
Specifications    Instructions