| DC to DC Transmitters
| Looptracker® LEDs Push to Test Built-In Loop Power Supply Lifetime Warranty |
|
Model
|
Input
|
Output Ranges
|
Features
|
Data & Applications
|
Photo
|
API 4010 G
Non-Isolated DC-DC Transmitter
with Loop Power Supply Specify Input, Output & Power
| Factory Configured Others available 0-100mVDC to 0-500VDC ±100mVDC to ±10VDC 0-1mADC to 0-900mADC
| Factory Configured Others available 0-1V 0-5V 1-5V 0-10V ±5V ±10V 0-1mA 0-20mA 4-20mA
| Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test 18 V Loop Power Supply Uses 8-Pin Socket
|
Data Sheet
ApplicationsConvert a Control Signal for a Process
Reference
Ground Loops
RFI / EMI
|
|
API 4050 G
Non-Isolated DC-DC Transmitter
Narrow Input Span
with Loop Power Supply Specify Input, Output & Power
| Factory Configured Others available 0-10mVDC to 0-100mVDC ±50mVDC 0-100ADC to 0-1mADC
| Factory Configured Others available 0-1V 0-5V 1-5V 0-10V ±5V ±10V 0-1mA 0-20mA 4-20mA
| Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test 18 V Loop Power Supply Uses 8-Pin Socket
| Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4300 G
Isolated DC-DC Transmitter
with Loop Power Supply Specify Input, Output & Power
| Factory Configured Others available 0-100mVDC to 0-500VDC ±100mVDC - ±10VDC 0-1mADC to 0-900mADC
| Factory Configured Others available 0-1V 0-5V 1-5V 0-10 ±5V ±10V 0-1mA 0-20mA 4-20mA
| Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation 18 V Loop Power Supply Uses 8-Pin Socket
| Data Sheet
Applications
Motor Load Control Monitoring Motor Speed with a PLC
Manual Override of Computer Control
Monitoring Pressure w. a PLC
Monitoring Product Moved by Conveyor
Phase Separator Water Level Control
Reference
Ground Loops
RFI / EMI
|
|
API 4310 G
Isolated DC-DC Transmitter
Narrow Input Span with Loop Power Supply Specify Input, Output & Power
| Factory Configured Others available 0-10mVDC to 0-100mVDC ±50mVDC 0-100ADC to 0-1mADC
| Factory Configured Others available 0-1V 0-5V 1-5V 0-10V ±5V ±10V 0-1mA 0-20mA 4-20mA
| Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation 18 V Loop Power Supply Uses 8-Pin Socket
| Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4380 G
Field Selectable
Isolated DC-DC Transmitter
with Loop Power Supply Specify Power
| 24 Field Settable 0-50mVDC to ±10VDC 0-1mADC to 0-20mADC Others available
| 16 Field Settable 0-1V to ±10V 0-2mA to 0-20mA 4-20mA
| Minuteman Setup Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation 18 V Loop Power Supply Uses 8-Pin Socket
| Data Sheet
Help Sheet
Range Settings
Reference
Ground Loops
RFI / EMI
|
|
API 4380 GHV3
Field Selectable
Isolated DC-DC Transmitter
High Voltage Input Specify Power
| 24 Field Settable 0-1VDC to ±200VDC Others available
| 16 Field Settable 0-1V to ±10V 0-2mA to 0-20mA 4-20mA
| Minuteman Setup Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation Uses 8-Pin Socket
| Data Sheet
Range Settings
Reference
Ground Loops
RFI / EMI
|
|
API 4380 DIN
Field Selectable
Isolated DC-DC Transmitter
80-265 VAC or 48-300 VDC Powered
| 24 Field Settable 0-50mVDC to ±10VDC 0-1mADC to 0-20mADC Others available
| 16 Field Settable 0-1V to ±10V 0-2mA to 0-20mA 4-20mA
| Minuteman Setup Looptracker® LEDs for Input and Output Push to Test Full Isolation 12 V Loop Power Supply DIN package 22.5 mm W Universal Power
| Data Sheet
Help Sheet
Applications
Controlling and Monitoring Liquid Flow From a Single Flow Meter
Reference
Ground Loops
RFI / EMI
|
|
API 4380 DIN DD
Field Selectable
Isolated DC-DC Transmitter
9-30 VDC Powered |
API 4385 G
Field Selectable
Isolated DC-DC Transmitter
Wide Ranging w. Input Offset with Loop Power Supply Specify Power
| 24 Field Settable 0-50mVDC to 0-20VDC 0-200µADC to 0-40mADC Others available Selectable Zero Offset
| 16 Field Settable 0-1V to ±10V 0-2mA to 0-20mA 4-20mA
| Minuteman Setup Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation 18 V Loop Power Supply Uses 8-Pin Socket
| Data Sheet
Range Settings
Reference
Ground Loops
RFI / EMI
|
|
DPI HV-DC
Factory Set FieldChangeable
Isolated DC-DC Transmitter High Voltage Input Specify Input, Output & 115 VAC or 230 VAC Powered
| 7 Standard, 1 Custom
Factory set, can be changed in the field 0-100VDC to 0-2000VDC
| 16 Ranges Factory set, can be changed in the field
0-1V to ±10V 0-2mA to 0-20mA 4-20mA
| Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
| Data Sheet
Range Settings
Reference
Ground Loops
RFI / EMI
|
|
API 4390
Factory Set
2 Channel DC-DC Transmitter Isolator Specify Input, Output & Power
| Factory Configured DC Volts or mA 2 Independent Channels 0-100mVDC to 0-100VDC 0-1mADC to 4-20 mADC
| Factory Configured DC Volts or mA 2 Independent Channels 0-100mVDC to 0-100VDC 0-1mADC to 4-20 mADC
| Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
| Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4391
Factory Set
2 Channel DC-DC Transmitter Isolator Specify Input, Output & Power
| Factory Configured DC Volts or mA 2 Independent Channels 0-100mVDC to 0-100VDC 0-1mADC to 4-20 mADC
| Factory Configured Bipolar DC Volts 2 Independent Channels ±5VDC, ±10VDC Others Available
| Looptracker± LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
| Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4392
Factory Set
2 Channel DC-DC Transmitter Isolator Specify Input, Output & Power
| Factory Configured Bipolar DC Volts or mA 2 Independent Channels ±5VDC, ±10VDC Others Available
| Factory Configured Bipolar DC Volts or mA 2 Independent Channels ±5VDC, ±10VDC Others Available
| Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
| Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4393
IsoSplitter
Factory Set
DC-DC Signal Splitter Isolator Specify Input, Output & Power
| Factory Configured Others available 0-50mVDC to ±10VDC 0-1mADC to 0-20mADC, 4-20mADC
| Factory Configured 2 Independent Channels 0-50mVDC to ±10VDC 0-1mADC to 0-20mADC, 4-20mADC Others available
| Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
| Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4393 L1
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator Specify Power
| Factory Configured 4-20 mA 18 V Source
| Factory Configured 2 Independent Channels Ch.1: 4-20 mA 18 V Source Ch.2: 4-20 mA 18 V Source
| Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
| Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4393 L1 EX1
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator Specify Power
| Factory Configured 4-20 mA 18 V Source
| Factory Configured 2 Independent Channels Ch.1: 4-20 mA Current Sinking Ch.2: 4-20 mA 18 V Source
| Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
| Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4393 L1 EX2
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator Specify Power
| Factory Configured 4-20 mA 18 V Source
| Factory Configured 2 Independent Channels Ch.1: 4-20 mA 18 V Source Ch.2: 4-20 mA Current Sinking
| Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
| Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4393 L1 EX3
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator Specify Power
| Factory Configured 4-20 mA 18 V Source
| Factory Configured 2 Independent Channels Ch.1: 4-20 mA Current Sinking Ch.2: 4-20 mA Current Sinking
| Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
| Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
LPI-1
Loop-Powered Isolator
| Factory Configured 4-20 mA Others Available
| Factory Configured 4-20 mA Others Available
| Hot-Swappable Plug-In Design Looptracker® LED for Output Push to Test Uses 8-Pin Socket
| Data Sheet
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops
RFI / EMI
|
|
LPI-2
Loop-Powered Isolator, 2 Independent Channels
| Factory Configured 2 Independent 4-20 mA Others Available
| Factory Configured 2 Independent 4-20 mA Others Available |
DPI-2
Loop-Powered Isolator, 2 Channel
| Factory Configured 2 Independent 4-20 mA Others Available
| Factory Configured 2 Independent 4-20 mA Others Available
| Looptracker® LED for Output Push to Test DIN package 22.5 mm W
| Data Sheet
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops
RFI / EMI
|
|