API
1000 G
DC Input DPDT Alarm
|
| DC
Voltage or Current
Specify Range
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1020 G
DC Input Dual SPDT Alarms
| DC
Voltage or Current
Specify Range
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1005 G
4-20 mA
Input DPDT Alarm
|
| 4-20
mA
18V Loop Supply
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1025 G
4-20 mA
Input Dual SPDT Alarms
| 4-20
mA
18V Loop Supply
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1040 G
DC Input SPDT Alarm +
Transmitter
|
| DC
Voltage or Current
Specify Range
18V Loop Supply
| 1
SPDT Contact Set
Field Adjustable Hi Alarm
Non-Isolated DC Voltage or
Current Transmitter
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
APD
1080
Fast Field Selectable Setup
DC Input Single DPDT Alarm
Trip with Input Loop Power Supply
|
| 24
Field Configurable Input Ranges
Min: 0-50 mVDC
Max: ±10 VDC
Min: 0-1 mADC
Max: 0-20 mADC mA
input can be wired for Sink or Source
| Field
Configurable Alarm
One DPDT 7A Contact Set
Adjustable Setpoint
| One-Minute
Setup
Removable Plugs
Input LoopTracker LED
Alarm status LED
Alarm Test Button
Full I/O/Power Isolation
Selectable Input Sink/Source
15 V Input Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC,
10-32 VAC Power |
API
1080 G
Field Settable
DC Input DPDT Alarm
1080
G Ranges
1080
G Help
|
| DC
Voltage or Current
Field Selectable Ranges
18V Loop Supply
Socket Sold Separately
| 1
DPDT Contact Set
Field Adjustable
Selectable Alarm Action
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1080 DIN
Field Settable
DC Input DPDT Alarm
|
| DC
Voltage or Current
Field Selectable Ranges
12V Loop Supply
| 1
DPDT Contact Set
Field Adjustable
Selectable Alarm Action
| 80-265
VAC
48-300 VDC |
API
1090 G
Field Settable DC Input
Dual SPDT Alarms
1090
G Ranges
1090
G Help
|
| DC
Voltage or Current
Field Selectable Ranges
18V Loop Supply
Socket Sold Separately
| 2
SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
APD
1090
Fast Field Selectable Setup
DC Input Dual SPDT Alarm Trip with Input Loop Power Supply
|
| 24
Field Configurable Input Ranges
Min: 0-50 mVDC
Max: ±10 VDC
Min: 0-1 mADC
Max: 0-20 mADC
| Field
Configurable Alarm
One DPDT 7A Contact Set
Adjustable Setpoint
| Minuteman
One-Minute Setup
Hot-Swappable Plug-In Design
LoopTracker LED
Alarm status LED
Output Test/Alarm Reset Button
18 V Loop Power Supply
Uses API-011 11-Pin Socket
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60) |
API
1090 DIN
Field Settable DC Input
Dual SPDT Alarms
|
| DC
Voltage or Current
Field Selectable Ranges
12V Loop Supply
| 2
SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
| 80-265
VAC
48-300 VDC |
API
1090 DD
Field Settable DC Input
Dual SPDT Alarms
| DC
Voltage or Current
Field Selectable Ranges
12V Loop Supply
| 2
SPDT Contact Sets
Field Adjustable
Selectable Alarm Action
| 9-30
VDC |
|
Thermocouple
Input Alarm Trips
|
|
| Download
Temperature Input pdf |
| Model
| Input
| Output
| Power |
API
1200 G
T/C Input DPDT
Alarm
|
| J,
K, T, E Thermocouple
Specify Type & Range
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1220 G
T/C Input Dual SPDT
Alarms
| J,
K, T, E Thermocouple
Specify Type & Range
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Types
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
| Sineax
V624
Programmable
Isolated RTD or
T/C to DC Transmitter
Microprocessor Based

|
| RTD
2-, 3-, or 4-wire
100 Ω
0.00385a
100 Ω
0.003916a
T/C types
J, K, T, E, R, S, N, B, W5, W3, L, U
Thermistor
Custom
| Specify
if Current or Voltage
Output
0-2 mA to
0-20 mA,
20-0 mA
0-1 V to
0-10 V,
10-0 V
| PC
Programmable
Reverse Output Programmable
Custom Input Linearization
Programmable Sensor Fault Response
Removable Plugs
3.7 kV Input/Output/Power Isolation
24-60 or 85-230 VAC/VDC Powered
Software
Instructions
|
API
4000 G
T/C or RTD Input Transmitter, Isolated
Field Rangeable
Note: This model discontinued and replaced
by Camille
Bauer V624
|
| J,
K, T, E, R, S Thermocouple
Most RTDs &
Resistance Elements
Field Selectable Type & Range
|
Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
|
115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
API
4100 G
T/C Input Transmitter,
Non-Isolated, Non-Linearized
|
| J,
K, T, E Thermocouple
Specify Type & Range
|
DC
Voltage or Current
Field Selectable Ranges
|
115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
API
4130 GL
T/C Input Transmitter,
Isolated, Linearized
| J,
K, T, E Thermocouple
Specify Type & Range
|
Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
|
115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
|
RTD
Input Alarm Trips
|
|
| Download
Temperature Input pdf |
| Model
| Input
| Output
| Power |
| Sineax
V624
Programmable
Isolated RTD or
T/C to DC Transmitter
Microprocessor Based

|
| RTD
2-, 3-, or 4-wire
100 Ω
0.00385a
100 Ω
0.003916a
T/C types
J, K, T, E, R, S, N, B, W5, W3, L, U
Thermistor
Custom
| Specify
if Current or Voltage
Output
0-2 mA to
0-20 mA,
20-0 mA
0-1 V to
0-10 V,
10-0 V
| PC
Programmable
Reverse Output Programmable
Custom Input Linearization
Programmable Sensor Fault Response
Removable Plugs
3.7 kV Input/Output/Power Isolation
24-60 or 85-230 VAC/VDC Powered
Software
Instructions
|
APD
1400
RTD
Input Single Alarm Trip
|
| Specify
RTD type and Temperature Range
Factory Configured
10 Ω
to 2000 Ω
RTD including
100 Ω
0.00385a
100 Ω
0.00391a,
10 Ω
Cu,
1000 Ω
Ni-Fe,
120 Ω
Ni or Special
| Single
setpoint dual SPDT Form C 8A contact set
Field Adjustable
Specify Alarm Type
Standard: HI alarm, non-latching, normal acting
Options: LO alarm, latching, reverse acting
See data sheet for alarm options
| DIN
Rail Mount without Tools
LoopTracker LED for Input
Alarm Status LEDs
Push to Test/Reset
2-Wire or 3-Wire RTD
Lead Wire Compensation for 3-Wire
Universal Power
D option for 9-30 VDC, 10-32 VAC Power |
APD
1420
RTD
Input Dual Alarm Trip

|
| Specify
RTD type and Temperature Range
Factory Configured
10 Ω
to 2000 Ω
RTD including
100 Ω
0.00385a
100 Ω
0.00391a,
10 Ω
Cu,
1000 Ω
Ni-Fe,
120 Ω
Ni or Special
| Two
setpoint dual SPDT Form C 8A contact sets
Field Adjustable
Specify Alarm Type
Standard: HI/LO alarm, non-latching, normal acting
Options: LO/LO, HI/HI, LO/HI alarms, latching, reverse acting
See data sheet for alarm options
| DIN
Rail Mount without Tools
LoopTracker LED for Input
Alarm Status LEDs
Push to Test/Reset
2-Wire or 3-Wire RTD
Lead Wire Compensation for 3-Wire
Universal Power
D option for 9-30 VDC, 10-32 VAC Power |
APD
1430
RTD
Input Band Alarm Trip

|
| Specify
RTD type and Temperature Range
Factory Configured
10 Ω
to 2000 Ω
RTD including
100 Ω
0.00385a
100 Ω
0.00391a,
10 Ω
Cu,
1000 Ω
Ni-Fe,
120 Ω
Ni or Special
| Two
setpoint dual SPDT Form C 8A contact sets
Field Adjustable
Specify Alarm Options
Standard: Band alarm (both alarms trip if outside LO and HI
trip points), non-latching, normal acting
Options: Inverse band alarm, latching, reverse acting
See data sheet for alarm options
| DIN
Rail Mount without Tools
LoopTracker LED for Input
Alarm Status LEDs
Push to Test/Reset
2-Wire or 3-Wire RTD
Lead Wire Compensation for 3-Wire
Universal Power
D option for 9-30 VDC, 10-32 VAC Power |
API
1400 G
RTD Input DPDT
Alarm
|
| 10
Ω to 2000 Ω RTDs
Factory Set Type & Range
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1420 G
RTD Input Dual SPDT
Alarms
| 10
Ω to 2000 Ω RTDs
Specify Type & Range
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Types
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4000 G
T/C or RTD Input Transmitter, Isolated
Field Rangeable
Note: This model discontinued and replaced
by Sineax V624
|
| Most
RTDs &
Resistance Elements
J, K, T, E, R, S Thermocouple
Field Selectable Type & Range
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4001 G
RTD Input Transmitter, Non-Isolated,
Non-Linearized
|
| 10
Ω to 2000 Ω RTDs
Specify Type & Range
| DC
Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4001 GL
RTD Input Transmitter, Isolated,
Linearized
| 10
Ω to 2000 Ω RTDs
Specify Type & Range
| Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4001 G SA-B
Differential 2 RTD Input Transmitter,
Non-Isolated,
Non-Linearized
|
| Two
100 Ω 0.00385 RTDs
For Differential Temperature
Factory Set,
Can Be Field Calibrated
| DC
Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
2000 Series
DuoPak®
Two Channel Isolated Transmitter
|
| Specify
Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Load Cell/Strain Gauge
See data sheet for input specifications and model numbers
| Specify
Output Range for Each Channel
Factory Configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
| Two
Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC or 48-300 VDC Powered
API 20xx DD for 9-30 VDC/
10-32 VAC Power (+$60)
|
T16L
Series
(F16LT)
ThermoPro®
Indicating RTD Transmitter
|
|
Specify RTD
Length and Fixed or Spring-Loaded RTD
Temperature Range
58.0°F to 392.0°F or
50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
| 4-20
mA Output is User Configurable Over the Temperature Range
| User-Programmable
4-20 mA
Output Range
0.1 Degree Display Resolution
Precision RTD Element
NEMA 4X Housing
2-Wire Design
Powered by 8-32 VDC 4-20 mA
Current Loop
316 Stainless Steel Probe
1/2" NPT Fitting for Standard
Thermowells
Spring-Loaded Probe for use
with Thermowells |
T16B
Series
ThermoPro®
Battery Powered RTD
Temperature Indicator
|
|
Specify RTD
Length and Fixed or Spring-Loaded RTD
Temperature Range
58.0°F to 392.0°F or
50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
| None
| 0.1
Degree Display Resolution
Precision RTD Element
NEMA 4X Housing
Powered by Two AA batteries (included)
316 Stainless Steel Probe
1/2" NPT Fitting for Standard Thermowells
Spring-Loaded Probe available for use with Thermowells |
T16ADA
Series
ThermoPro®
Battery Powered RTD
Temperature Indicator
|
|
Specify RTD
Length and Fixed or Spring-Loaded RTD
Temperature Range
58.0°F to 392.0°F or
50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
| 2
SPDT relays,
1 A @ 24 VDC,
0.5 A @ 115 VAC,
Non-inductive,
Fully programmable
| User-Programmable
Alarm Relays
0.1 Degree Display Resolution
Precision RTD Element
NEMA 4X Housing
Powered by 8-32 VDC, 10-32 VAC
316 Stainless Steel Probe
1/2" NPT Fitting for Standard Thermowells
Spring-Loaded Probe for use with Thermowells |
|
Frequency
Input Alarm Trips
|
|
| Download
Frequency pdf |
| Model
| Input
| Output
| Power |
| APD 7580
Field Selectable Minuteman
Setup
Frequency to DC Transmitter
Isolated

|
| 30 Field Configurable
Inputs
Low Range
100 Hz Increments
Min: 0-100 Hz
Max: 0-1500 Hz
High Range
2 kHz Increments
Min: 2 kHz
Max: 30 kHz
| 18 Field Configurable
Outputs
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
| Accepts
most frequency & prox sensors
Minuteman One-Minute Setup
Removable Plugs
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Selectable Output Sink/Source
15 V Sensor Power Supply
20 V Output Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC, 10-32 VAC Power |
API
2000 Series
DuoPak®
Two Channel Isolated Transmitter
|
| Specify
Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Load Cell/Strain Gauge
See data sheet for input specifications and model numbers
| Specify
Output Range for Each Channel
Factory Configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
| Two
Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC or 48-300 VDC Powered
API 20xx DD for 9-30 VDC/
10-32 VAC Power (+$60)
|
API
1700 G
Frequency Input DPDT Alarm
|
| 10
Hz to 20 KHz
Specify Input Span
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1720 G
Frequency Input Dual SPDT Alarms
| 10
Hz to 20 KHz
Specify Input Span
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
7010 G
Frequency to
DC Transmitter, Isolated
|
| 10
Hz to 20 KHz
Specify Input Span
|
Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
7500 G
DC to Frequency Transmitter,
Isolated
7500
G Ranges
7500
G Help
|
| DC
Voltage or Current
Field Selectable Ranges
18V Loop Supply
| Fully
Isolated
0-100 Hz to 0-30 KHz
Field Selectable
Specify Open Col. or TTL
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
7500 G SS
DC to Low Frequency Transmitter, Isolated
7500 G SS Ranges
| DC
Voltage or Current
Field Selectable Ranges
18V Loop Supply
| Fully
Isolated
0-1 Hz to 0-300 Hz
Field Selectable
Specify Open Col. or TTL
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
7580 G
Frequency to
DC Transmitter, Isolated
Field Rangeable
7580
G Ranges
7580
G Help
|
| 100
Hz to 30 KHz
Field Selectable Ranges
18V Loop Supply
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
| RheinTacho
Speed Monitors
CR
CRR
CRA
CRRA
Field Programmable
Isolated
 
|
| Programmable
Min: 0-0.01 Hz
Max: 0-20,000 Hz
Optional Sensors:
Hall
Differential Hall
Magnetoresistive
See price list for standard sensors
| CR: 1 Relay
CRR: 2 Relays
CRA: 1 Relay & Analog Output
CRRA 2 Relays & Analog Output
Relay:
5A @ 250 VAC resistive or
2A @ 42 VDC resistive
Analog Output:
0-20mA or 4-20mA
| Field Programmable
DIN-rail mounted
Programmable Measuring Units
Programmable Relays
Programmable Delay and Reset
Full I/O/Power Isolation
18-36 VDC Powered
Instructions
|
|
AC
Input alarm Trips
|
|
| Download
AC Input pdf |
| Model
| Input
| Output
| Power |
API
2000 Series
DuoPak®
Two Channel Isolated Transmitter
|
| Specify
Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Load Cell/Strain Gauge
See data sheet for input specifications and model numbers
| Specify
Output Range for Each Channel
Factory Configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
| Two
Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC or 48-300 VDC Powered
API 20xx DD for 9-30 VDC/
10-32 VAC Power (+$60)
|
API
1600 G
AC
Input DPDT Alarm
|
| AC
Voltage or Current
Specify Range
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1620 G
AC
Input Dual SPDT Alarms
| AC
Voltage or Current
Specify Range
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
6010 G
AC
to DC Transmitter, Isolated
|
| AC
Voltage or Current
Specify Range
18V Loop Supply
| Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
6010 G 5A &
API
6010 G 20A
C to DC Transmitters, Isolated
High Current
|
| AC
Current (up to 20 A)
Specify Range
Socket & Shunt Included
| Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
APD
6380
Field
Selectable Minuteman Setup
AC
to DC Transmitter
Isolated
|
Removable
Plugs!
| Hundreds
of Field Configurable
Input Ranges
0-40 mVAC to
0-300 VAC
0-4 mAAC to
0-200 mAAC
APD
6380 ranges
| 18
Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
Others available
| Minuteman
One-Minute Setup
Removable Plugs
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Selectable Sink/Source
20 V Output Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC, 10-32 VAC Power
|
API
6380 G
AC
to DC Transmitter, Isolated
Field Rangeable
6380
G Ranges
6380
G Help
|
| 20
Field Configurable Input Ranges
0-50 mVAC to
0-250 VAC
0-5 mAAC to
0-200 mAAC
For >200mAAC to 5 Amps use Socket/Shunt Resistor API-008-5A
|
16
Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
|
Minuteman
One-Minute Setup
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Uses API-008 8-Pin Socket
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60)
|
API
6380 G HV
True Field Selectable
Minuteman Setup
AC
to DC Transmitter
Isolated, High Voltage Input
| 24
Field Configurable Input Ranges
Same as API 6380 but with 0 to 300 VAC, 0-400 VAC, 0-500 VAC, 0-600
VAC input ranges in addition to standard ranges
|
16
Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mAs
|
Minuteman
One-Minute Setup
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Uses API-008 8-Pin Socket
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60)
|
API
6380 G S
Field
Selectable
Minuteman Setup
True
RMS AC to DC
Transmitter Isolated
|
| 20
Field Configurable Input Ranges
0-50 mVAC to
0-250 VAC
0-5 mAAC to
0-200 mAAC
For >200mAAC to 5 Amps use Socket/Shunt Resistor API-008-5A
|
16
Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mAs
|
Minuteman
One-Minute Setup
True RMS for Distorted Waveforms
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Uses API-008 8-Pin Socket
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60)
|
API
6380 G SHV
Field Selectable
Minuteman Setup
True
RMS AC to DC
Transmitter Isolated,
High Voltage Input
| 24
Field Configurable Input Ranges
Same as API 6380 but with 0 to 300 VAC, 0-400 VAC, 0-500 VAC, 0-600
VAC input ranges in addition to standard ranges
|
16
Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mAs
|
Minuteman
One-Minute Setup
True RMS for Distorted Waveforms
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Uses API-008 8-Pin Socket
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60)
|
|
Potentiometer
Input Alarm Trips
|
|
| Download
Potentiometer Input pdf |
| Model
| Input
| Output
| Power |
API
2000 Series
DuoPak®
Two Channel Isolated Transmitter
|
| Specify
Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Load Cell/Strain Gauge
See data sheet for input specifications and model numbers
| Specify
Output Range for Each Channel
Factory Configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
| Two
Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC or 48-300 VDC Powered
API 20xx DD for 9-30 VDC/
10-32 VAC Power (+$60)
|
API
1800 G
Potentiometer Input DPDT Alarm
|
| 0-100
Ω to
0-1 Mega Ω
Potentiometer
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1820 G
Potentiometer Input Dual SPDT
Alarms
| 0-100
Ω to
0-1 Mega Ω
Potentiometer
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4003 G
Potentiometer to DC Transmitter,
Non-Isolated
|
| 0-100
Ω to
0-1 Mega Ω
Potentiometer
| DC
Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4003 G I
Potentiometer to DC Transmitter,
Isolated
| 0-100
Ω to
0-1 Mega Ω
Potentiometer
| Fully
Isolated
DC Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4008 G
Potentiometer to DC Transmitter,
Isolated
Field Rangeable
|
| 0-100
Ω to
0-1 Mega Ω
Potentiometer
| Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
| APD
4008
Field Selectable Minuteman
Setup
Isolated Potentiometer
to DC Transmitter
|
| Any Potentiometer
0-100 O to
0-1 Mega Ω
0 to 90% Offset Capable
Can Use Partial Potentiometer Ranges
| 18 Field Configurable Outputs
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
| Minuteman One-Minute Setup
Removable Plugs
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Selectable Output Sink/Source
20 V Output Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC, 10-32 VAC Power |
|
Strain
Gauge, Bridge,
Load Cell
Input Alarm Trips
|
|
| Download
Strain Gauge Input pdf |
| Model
| Input
| Output
| Power |
API
1500 G
Strain
Gauge Input DPDT Alarm
|
| Strain
Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
| 1
DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
1520 G
Strain
Gauge Input Dual SPDT Alarms
| 2
SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4051 G
Single Strain Gauge
to
DC Transmitter,
Non-Isolated
|
| Strain
Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
| DC
Voltage or Current
Specify Range
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4058 G
1-4 Strain Gauge to
DC Transmitter,
Non-Isolated
4058
G Ranges
4058
G Help
|
| 1
to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
|
DC
Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
4059 G
1-4 Strain Gauge to
DC Transmitter, Isolated
4059
G Help
4059
G Ranges
|
| 1
to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
|
Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
| APD
4059
Field Selectable Minuteman
Setup
Isolated Bridge to DC
Transmitter
Isolated

|
| Field Configurable
0-5 mVDC to
0-400 mVDC
Field Settable Excitation Voltage
0-10 VDC in 1 VDC Steps
| 18 Field Configurable Outputs
0-1 V to ±1 0V
0-2 mA to 0-2 0mA
4-20 mA
| Minuteman One-Minute
Setup
I/O LoopTracker LEDs
Full I/O/Power Isolation
Internal Bridge Excitation Source
Drive up to 4 bridges
Output Test Button
DIN rail mount
22.5 mm Wide
80-265 VAC, 48-300 VDC Powered
Option D for 9-30 VDC, 10-32 VAC Power |
API
2000 Series
DuoPak®
Two Channel Isolated Transmitter
|
| Specify
Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Load Cell/Strain Gauge
See data sheet for input specifications and model numbers
| Specify
Output Range for Each Channel
Factory Configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
| Two
Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC or 48-300 VDC Powered
API 20xx DD for 9-30 VDC/
10-32 VAC Power (+$60)
|
|
API
4059 DIN
1-4 Strain Gauge to
DC Transmitter, Isolated
4059
DIN Ranges
|
| 1
to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
|
Fully
Isolated
DC Voltage or Current
Field Selectable Ranges
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API
SUM 000
Strain
Gauge Summing Board
API
SUM 025
Summing
Board with API 4059
API
SUM 100
Summing
Board w. NEMA 4X Box
API
SUM 125
Summing
Board, API 4059, NEMA 4X Box
|
| Summing
Assembly Board
1 to 4 Strain Gauges,
Bridges, or Load Cells
Individually Adjustable
Excitation & Signal Trim
Optional SS Housing
|
DC
Voltage or Current
Use with 4058 G or
4059 G
| 115
VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
|
Module
Accessories
|
|
| Click
here to download Accessories pdf |
| Sockets
& Housings
|

| 8-Pin,
11-Pin Sockets
8-Pin, 11-Pin Finger-Safe Sockets
DIN Rail
Module Housings |