Frequency Module/Alarm/Transmitter

 Frequency Alarm
 Frequency Transmitter
 Hot-Swappable Plug-In Design
  Looptracker LEDs
  Push to Test
  Lifetime Warranty
Model Input Output Ranges Features Data & Applications Photo
APD 7580

Field Selectable Minuteman Setup

Frequency to DC Transmitter
Isolated

30 Field Configurable Inputs
Low Range
100 Hz Increments
Min: 0-100 Hz
Max: 0-1500 Hz
High Range
2 kHz Increments
Min: 2 kHz
Max: 30 kHz
18 Field Configurable Outputs
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA

Accepts most frequency & prox sensors
Minuteman One-Minute Setup
Removable Plugs
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Selectable Output Sink/Source
15 V Sensor Power Supply
20 V Output Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC, 10-32 VAC Power
Data Sheet

Applications

Remote Monitoring of Motor Speed
HVAC Variable Air Volume Control
Control and Record Water Flow
Auto-Ranging Flow Meter
Hall-Effect Flow Sensor
Control and Record Water Flow
Monitoring & Totalizing Flow
Monitoring & Totalizing Flow Meter Output

Reference Info

Alarm Terminology
Deadband

Relay Protection & EMI Suppression
RFI / EMI


API 2000 Series
DuoPak®

Two Channel Isolated Transmitter

Specify Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Strain Gauge
See data sheet for input specifications and model numbers
Specify Output Range for Each Channel
Factory Configured
0-1 V,
0-5 V,
1-5 V,
0-10 V
±5 V,
±10 V
0-1 mA,
0-20 mA,
4-20 mA
Others available
Two Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC, 48-300 VDC Power
API 20xx DD for 9-30 VDC,
10-32 VAC Power (+$60)
Data Sheet

Applications
Remote Monitoring of Motor Speed
HVAC Variable Air Volume Control
Control and Record Water Flow
Auto-Ranging Flow Meter
Hall-Effect Flow Sensor
Control and Record Water Flow
Monitoring & Totalizing Flow
Monitoring & Totalizing Flow Meter Output

Reference Info

Alarm Terminology
Deadband

Relay Protection & EMI Suppression
RFI / EMI
API 1700 G
Frequency Input Single Alarm Trip
Specify Input, Alarm Type & Power


API 1720 G
Frequency Input Dual Alarm Trip
Specify Input, Alarm Type & Power

Factory Configured
Minimum: 10Hz
Maximum: 20 kHz
100mV to 150V RMS
Factory Configured Alarm Type
1 or 2 Field
Adjustable Setpoint(s)
7A SPDT
Alarm Relays
Hot-Swappable Plug-In Design
Looptracker® LEDs for Input
Alarm Status LEDs
Push to Test/Reset
Uses 11-Pin Socket

Data Sheet

Applications

Monitor Computer & Process Status

Reference Info

Alarm Terminology
Deadband

Relay Protection & EMI Suppression
RFI / EMI




API 7010 G
Isolated Frequency to DC Transmitter
Specify Input, Output & Power
Factory Configured
Minimum: 10Hz
Maximum: 20 kHz
100mV to 150V RMS
Factory Configured
Others available
0-1V
0-5V
1-5V
0-10V
±5V
±10V
0-20mA
4-20mA
Hot-Swappable Plug-In Design
Looptracker® LEDs for Input and Output
Full Isolation
Push to Test
Uses 8-Pin Socket
Data Sheet

Applications

Remote Monitoring of Motor Speed
Hall-Effect Flow Sensor

Reference Info

RFI / EMI



API 7500 G
Field Selectable
Isolated DC to Frequency Transmitter
Specify Power
24 Field Settable
0-50mVDC to
±10VDC
0-1mADC to
0-20mADC
30 Field Settable
Low Range
100Hz Increments
Min: 0-100Hz
Max: 0-1500Hz
High Range
2kHz Increments
Min: 2kHz
Max: 30kHz
Minuteman Setup
Hot-Swappable Plug-In Design
Looptracker LEDs for Input & Output
Push to Test
Full Isolation
Uses 8-Pin Socket
Data Sheet

Range Settings

Help Sheet

Applications

Monitoring & Totalizing Flow
Remote Monitoring of Motor Speed

Reference Info

RFI / EMI


Socket sold separately

API 7500 G SS
Field Selectable
Isolated DC to Low Frequency Transmitter
Specify Power
24 Field Settable
0-50mVDC to
±10VDC
0-1mADC to
0-20mADC
30 Field Settable
Low Range
1Hz Increments
Min: 0-1Hz
Max: 0-15Hz
High Range
20Hz Increments
Min: 20Hz
Max: 300Hz
Minuteman Setup
Hot-Swappable Plug-In Design
Looptracker® LEDs for Input & Output
Push to Test
Full Isolation
Uses 8-Pin Socket
Data Sheet

Range Settings

Reference Info

RFI / EMI


Socket sold separately


API 7580 G
Field Selectable
Isolated Frequency to DC Transmitter
Specify Power
30 Field Settable
Low Range
100Hz Increments
Min: 0-100Hz
Max: 0-1500Hz
High Range
2kHz Increments
Min: 2kHz
Max: 30kHz
16 Field Settable
0-1V to ±10V
0-2mA to 0-20mA
4-20mA
Minuteman Setup
Hot-Swappable Plug-In Design
Looptracker® LEDs for Input & Output
Push to Test
Full Isolation
Uses 8-Pin Socket
Data Sheet

Range Settings

Help Sheet

Applications

HVAC Variable Air Volume Control
Control and Record Water Flow
Auto-Ranging Flow Meter

Reference Info

RFI / EMI


Socket sold separately


RheinTacho Speed Monitors
CR Frequency Alarm
CRR Frequency Dual Alarm
CRA Frequency Transmitter & Alarm
CRRA Frequency Transmitter & Dual Alarm
Field Programmable
Isolated
Programmable
Min: 0-.01Hz
Max: 0-20,000 Hz
Uses Hall, Dif. Hall, or
Magnetoresistive sensors
Relay(s)
5A @ 250 VAC resistive or
2A @ 42 VDC resistive

Optional Analog Output
0-20mA or 4-20mA

Minuteman Setup
Hot-Swappable Plug-In Design
Looptracker® LEDs for Input & Output
Push to Test
Full Isolation
Uses 8-Pin Socket
Field Programmable
DIN-rail mounted
Programmable Measuring Units
Programmable Relays
Programmable Delay and Reset
Full I/O/Power Isolation
Power; 18-36VDC


Sensors sold separately