DC Input Alarm Trips
|
|
| Download DC Input pdf |
| Model
| Input
| Output
| Power |
API 1000 G
DC Input DPDT Alarm
|
| DC Voltage or Current Specify Range
| 1 DPDT Contact Set Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1020 G
DC Input Dual SPDT Alarms
| DC Voltage or Current Specify Range
| 2 SPDT Contact Sets Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1005 G
4-20 mA Input DPDT Alarm
|
| 4-20 mA 18V Loop Supply
| 1 DPDT Contact Set Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1025 G
4-20 mA Input Dual SPDT Alarms
| 4-20 mA 18V Loop Supply
| 2 SPDT Contact Sets Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1040 G
DC Input SPDT Alarm + Transmitter
|
| DC Voltage or Current Specify Range 18V Loop Supply
| 1 SPDT Contact Set Field Adjustable Hi Alarm Non-Isolated DC Voltage or Current Transmitter Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1080 G
Field Settable DC Input DPDT Alarm
1080 G Ranges
1080 G Help
|
| DC Voltage or Current Field Selectable Ranges 18V Loop Supply Socket Sold Separately
| 1 DPDT Contact Set Field Adjustable Selectable Alarm Action
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1080 DIN
Field Settable DC Input DPDT Alarm
|
| DC Voltage or Current Field Selectable Ranges 12V Loop Supply
| 1 DPDT Contact Set Field Adjustable Selectable Alarm Action
| 80-265 VAC 48-300 VDC |
API 1090 G
Field Settable DC Input Dual SPDT Alarms
1090 G Rangmod_pdf/api_rangesheet/es
1090 G Help
|
| DC Voltage or Current Field Selectable Ranges 18V Loop Supply Socket Sold Separately
| 2 SPDT Contact Sets Field Adjustable Selectable Alarm Action
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1090 DIN
Field Settable DC Input Dual SPDT Alarms
|
| DC Voltage or Current Field Selectable Ranges 12V Loop Supply
| 2 SPDT Contact Sets Field Adjustable Selectable Alarm Action
| 80-265 VAC 48-300 VDC |
API 1090 DD
Field Settable DC Input Dual SPDT Alarms
| DC Voltage or Current Field Selectable Ranges 12V Loop Supply
| 2 SPDT Contact Sets Field Adjustable Selectable Alarm Action
| 9-30 VDC |
|
DC - DC Transmitters
|
|
| Download DC Input pdf |
| Model
| Input
| Output
| Power |
API 4010 G
DC-DC Transmitter, Non-Isolated
|
| DC Voltage or Current Specify Range 18V Loop Supply
| DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4050 G
DC-DC Transmitter, Non-Isolated Narrow Input Span
| DC Voltage or Current Specify Range Narrow Input Span 18V Loop Supply
| DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4300 G
DC-DC Transmitter, Isolated
|
| DC Voltage or Current Factory Set Range 18V Loop Supply
| Fully Isolated DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4310 G
DC-DC Transmitter, Isolated Narrow Input Span
| DC Voltage or Current Specify Range Narrow Input Range 18V Loop Supply
| Fully Isolated DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4380 G
DC-DC Transmitter, Isolated Field Rangeable4380 G Ranges
4380 G Help
|
| DC Voltage or Current Field Selectable Ranges 18V Loop Supply
| Fully Isolated C Voltage or Current Field Selectable Ranges
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4380 GHV3 Hi Voltage DC-DC Transmitter, Isolated Field Rangeable4380 GHV3 Ranges
| DC Voltage or Current Field Selectable Ranges High Voltage Input to 200 VDC 18V Loop Supply
| Fully Isolated DC Voltage or Current Field Selectable Ranges
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4380 DIN
DC-DC Transmitter, Isolated Field Rangeable4380 DIN Help
|
| DC Voltage or Current Field Selectable Ranges 12V Loop Supply
| Fully Isolated DC Voltage or Current Field Selectable Ranges
| 80-265 VAC 48-300 VDC |
API 4380 DD
DC-DC Transmitter, Isolated Field Rangeable
4380 DIN Help
| DC Voltage or Current Field Selectable Ranges 12V Loop Supply
| Fully Isolated DC Voltage or Current Field Selectable Ranges
| 9-30 VDC |
API 4385 G
DC-DC Transmitter, Isolated Field Rangeable
4385 G Ranges
|
| DC Voltage or Current Field Selectable Ranges True Offset Non-Interacting Controls 18V Loop Supply
| Fully Isolated DC Voltage or Current Field Selectable Ranges
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
DPI HV-DC
Hi Voltage DC-DC Transmitter, Isolated Field Rangeable
DPI HV-DC Ranges
|
| High Voltage DC 0-100VDC to 0-1200VDC
| Fully Isolated DC Voltage or Current Field Selectable Ranges
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
|
API 4390
2 Channel DC-DC Transmitter, Isolated
|
| DC Volts or mA 2 Independent Channels
| Fully Isolated DC Voltage or Current 2 Independent Channels
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VAC/VDC |
API 4391
2 Channel DC-DC Transmitter, Isolated, Bipolar Output
|
| DC Volts or mA 2 Independent Channels
| Fully Isolated Bipolar 5 Volts or 10 Volts 2 Independent Channels
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VAC/VDC |
API 4392
2 Channel DC-DC Transmitter, Isolated, Bipolar Input & Output
|
| Bipolar DC Volts or mA 2 Independent Channels
| Fully Isolated Bipolar DC Volts or mA 2 Independent Channels
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VAC/VDC |
API 4393
IsoSplitter 
DC-DC Signal Splitter, Isolated
|
| One DC Voltage or Current
| Fully Isolated Two Independent DC Voltage or Current Channels
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VAC/VDC |
API 4393 L1
IsoSplitter

DC-DC Signal Splitter, Isolated Sourced Input, Source or Sink Outputs
|
| One 4-20 mA 18V Loop Power Supply
| Fully Isolated Two Independent 4-20 mA Channels Source or Sink Outputs
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VAC/VDC |
|
Loop-Powered Isolators
|
|
| Download DC Input pdf |
| Model
| Input
| Output
| Power |
API LPI-1
Loop-Powered Isolator
|
| 4-20 mA
| Fully Isolated 4-20 mA
| Loop Powered |
API LPI-2
Dual Channel Loop-Powered Isolator
| Two 4-20 mA
| Fully Isolated Two 4-20 mA
| Loop Powered |
DPI-2
Dual Channel Loop-Powered Isolator
|
| Two 4-20 mA
| Fully Isolated Two 4-20 mA
| Loop Powered |
|
Loop Power Supplies
|
|
| |
| Model
| Input
| Output
| Power |
API 9046 Power Supplies
|

|
115 VAC Std. Opt. 230 VAC
|
Isolated Regulated DC Voltage Specify 5 to 32 VDC
|
115 VAC Std. Opt. 230 VAC
|
API 9046 CH
Bipolar Power Supplies
|
115 VAC Std. Opt. 230 VAC
|
Isolated Regulated DC Voltage Bipolar (±) Output VDC Specify ±5 to ±15 VDC
|
115 VAC Std. Opt. 230 VAC
|
|
Thermocouple Input
|
|
| Download Temperature Input pdf |
| Model
| Input
| Output
| Power |
API 1200 G
T/C Input DPDT Alarm
|
| J, K, T, E Thermocouple Specify Type & Range
| 1 DPDT Contact Set Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1220 G
T/C Input Dual SPDT Alarms
| J, K, T, E Thermocouple Specify Type & Range
| 2 SPDT Contact Sets Field Adjustable Specify Alarm Types
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4000 G
T/C or RTD Input Transmitter, Isolated
Field Rangeable
Note: This model discontinued and replaced by
Camille Bauer VK624
|
| J, K, T, E, R, S Thermocouple Most RTDs & Resistance Elements Field Selectable Type & Range
|
Fully Isolated DC Voltage or Current Field Selectable Ranges
|
115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC
|
API 4100 G
T/C Input Transmitter, Non-Isolated, Non-Linearized
|
| J, K, T, E Thermocouple Specify Type & Range
|
DC Voltage or Current Field Selectable Ranges
|
115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC
|
API 4130 GL
T/C Input Transmitter, Isolated, Linearized
| J, K, T, E Thermocouple Specify Type & Range
|
Fully Isolated DC Voltage or Current Field Selectable Ranges
|
115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC
|
|
RTD Input
|
|
| Download Temperature Input pdf |
| Model
| Input
| Output
| Power |
API 1400 G
RTD Input DPDT Alarm
|
| 10 Ω to 2000 Ω RTDs Factory Set Type & Range
| 1 DPDT Contact Set Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1420 G
RTD Input Dual SPDT Alarms
| 10 Ω to 2000 Ω RTDs Specify Type & Range
| 2 SPDT Contact Sets Field Adjustable Specify Alarm Types
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4000 G
T/C or RTD Input Transmitter, Isolated
Field Rangeable
Note: This model discontinued and replaced by
Camille Bauer V624
|
| Most RTDs & Resistance Elements J, K, T, E, R, S Thermocouple Field Selectable Type & Range
| Fully Isolated DC Voltage or Current Field Selectable Ranges
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4001 G
RTD Input Transmitter, Non-Isolated, Non-Linearized
|
| 10 Ω to 2000 Ω RTDs Specify Type & Range
| DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4001 GL
RTD Input Transmitter, Isolated, Linearized
| 10 Ω to 2000 Ω RTDs Specify Type & Range
| Fully Isolated DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4001 G SA-B
Differential 2 RTD Input Transmitter, Non-Isolated, Non-Linearized
|
| Two 100 Ω 0.00385 RTDs For Differential Temperature Factory Set, Can Be Field Calibrated
| DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
|
Frequency Modules
|
|
| Download Frequency pdf |
| Model
| Input
| Output
| Power |
API 1700 G
Frequency Input DPDT Alarm
|
| 10 Hz to 20 KHz Specify Input Span
| 1 DPDT Contact Set Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1720 G
Frequency Input Dual SPDT Alarms
| 10 Hz to 20 KHz Specify Input Span
| 2 SPDT Contact Sets Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 7010 G
Frequency to DC Transmitter, Isolated
|
| 10 Hz to 20 KHz Specify Input Span
|
Fully Isolated DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 7500 G
DC to Frequency Transmitter, Isolated
7500 G Ranges
7500 G Help
|
| DC Voltage or Current Field Selectable Ranges 18V Loop Supply
| Fully Isolated 0-100 Hz to 0-30 KHz Field Selectable Specify Open Col. or TTL
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 7500 G SS
DC to Low Frequency Transmitter, Isolated
7500 G SS Ranges
| DC Voltage or Current Field Selectable Ranges 18V Loop Supply
| Fully Isolated 0-1 Hz to 0-300 Hz Field Selectable Specify Open Col. or TTL
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 7580 G
Frequency to DC Transmitter, Isolated Field Rangeable
7580 G Ranges
7580 G Help
|
| 100 Hz to 30 KHz Field Selectable Ranges 18V Loop Supply
| Fully Isolated DC Voltage or Current Field Selectable Ranges
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
|
AC Input
|
|
| Download AC Input pdf |
| Model
| Input
| Output
| Power |
API 1600 G
AC Input DPDT Alarm
|
| AC Voltage or Current Specify Range
| 1 DPDT Contact Set Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1620 G
AC Input Dual SPDT Alarms
| AC Voltage or Current Specify Range
| 2 SPDT Contact Sets Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 6010 G
AC to DC Transmitter, Isolated
|
| AC Voltage or Current Specify Range 18V Loop Supply
| Fully Isolated DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 6010 G 5A &
API 6010 G 20A
C to DC Transmitters, Isolated High Current
|
| AC Current (up to 20 A) Specify Range Socket & Shunt Included
| Fully Isolated DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 6380 G
AC to DC Transmitter, Isolated Field Rangeable
6380 G Ranges
6380 G Help
|
| AC Voltage or Current Field Selectable Ranges 18V Loop Supply
|
Fully Isolated DC Voltage or Current Field Selectable Ranges
|
115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC
|
API 6380 G S
True RMS AC to DC Transmitter, Isolated Field Rangeable
6380 G S Ranges
6380 G S Help
| True RMS AC Voltage or Current Field Selectable Ranges 18V Loop Supply
|
Fully Isolated DC Voltage or Current Field Selectable Ranges
|
115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC
|
|
Potentiometer Input
|
|
| Download Potentiometer Input pdf |
| Model
| Input
| Output
| Power |
API 1800 G
Potentiometer Input DPDT Alarm
|
| 0-100 Ω to 0-1 Mega Ω Potentiometer
| 1 DPDT Contact Set Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1820 G
Potentiometer Input Dual SPDT Alarms
| 0-100 Ω to 0-1 Mega Ω Potentiometer
| 2 SPDT Contact Sets Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4003 G
Potentiometer to DC Transmitter, Non-Isolated
|
| 0-100 Ω to 0-1 Mega Ω Potentiometer
| DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4003 G I
Potentiometer to DC Transmitter, Isolated
| 0-100 Ω to 0-1 Mega Ω Potentiometer
| Fully Isolated DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4008 G
Potentiometer to DC Transmitter, Isolated Field Rangeable
|
| 0-100 Ω to 0-1 Mega Ω Potentiometer
| Fully Isolated DC Voltage or Current Field Selectable Ranges
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
|
Strain Gauge,
Bridge, Load Cell Input
|
|
| Download Strain Gauge Input pdf |
| Model
| Input
| Output
| Power |
API 1500 G
Strain Gauge Input DPDT Alarm
|
| Strain Gauge, Bridge, Load Cell Adjustable Excitation Specify Input Span
| 1 DPDT Contact Set Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 1520 G
Strain Gauge Input Dual SPDT Alarms
| 2 SPDT Contact Sets Field Adjustable Specify Alarm Type
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4051 G
Single Strain Gauge to DC Transmitter, Non-Isolated
|
| Strain Gauge, Bridge, Load Cell Adjustable Excitation Specify Input Span
| DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4058 G
1-4 Strain Gauge to DC Transmitter, Non-Isolated
4058 G Ranges
4058 G Help
|
| 1 to 4 Strain Gauges, Bridges, or Load Cells Field Selectable Ranges Adjustable Excitation
|
DC Voltage or Current Field Selectable Ranges
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4059 G
1-4 Strain Gauge to DC Transmitter, Isolated
4059 G Help
4059 G Ranges
|
| 1 to 4 Strain Gauges, Bridges, or Load Cells Field Selectable Ranges Adjustable Excitation
|
Fully Isolated DC Voltage or Current Field Selectable Ranges
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
|
API 4059 DIN
1-4 Strain Gauge to DC Transmitter, Isolated
4059 DIN Ranges
|
| 1 to 4 Strain Gauges, Bridges, or Load Cells Field Selectable Ranges Adjustable Excitation
|
Fully Isolated DC Voltage or Current Field Selectable Ranges
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API SUM 000
Strain Gauge Summing Board
API SUM 025
Summing Board with API 4059
API SUM 100
Summing Board w. NEMA 4X Box
API SUM 125
Summing Board, API 4059, NEMA 4X Box
|
| Summing Assembly Board 1 to 4 Strain Gauges, Bridges, or Load Cells Individually Adjustable Excitation & Signal Trim Optional SS Housing
|
DC Voltage or Current Use with 4058 G or 4059 G
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
|
Valve Position,
Math & P-I Converters
|
|
| Download Valve/Math pdf |
| Model
| Input
| Output
| Power |
API 3200 G
Valve Positioner/Actuator
|
| DC Voltage or Current Specify Range 100 Ω to 100 kΩ Feedback Pot
| Valve / Actuator Positioner / Controller 2 SPST Relays
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4400 G
(A+B+C+D) / 4 API 4401 G
(A+B+C) / 3 API 4402 G
(A+B) / 2 API 4403 G
(A+B+CD) / 3 API 4404 G
(A+BCD) / 4 API 4405 G
(ABCD) API 4406 G
(A+BC) / 2 API 4407 G
(ABC) API 4408 G
(AB)
|
| Up to 4 DC Voltage or Current Inputs Specify Ranges
| Addition, Subtraction, Averaging Versions Fully Isolated DC Voltage or Current Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
API 4440 G
DC to DC Transmitter, Square Root Extraction
|
| DC Voltage or Current Specify Range 18V Loop Supply
| Square Root Extraction Full Isolated DC Voltage or Current Square Root of Input Specify Range
| 115 VAC Std. Opt. 230 VAC Opt. 9-30 VDC |
DPG1000L3-15PSIG
Pressure to Current Converter
|
| 3.00 to 15.00 psig
| 4-20 mA
| Loop Powered |
F4L3-15PSIG
Pressure to Current Converter, NEMA 4X
|
| 3.00 to 15.00 psig
| 4-20 mA
| Loop Powered |
|
Module Accessories
|
|
| Download Accessories pdf |
| Sockets & Housings
|

| 8-Pin, 11-Pin Sockets 8-Pin, 11-Pin Finger-Safe Sockets DIN Rail Module Housings |
|
Current Sensors
|
|
| Download current Sensor pdf |
| Model
| Input
| Output
| Power |
CTX-ACR AC Current Transmitters
|
| True RMS 0-2 Amps to 0-200 Amps AC
| Isolated Output 4-20 mA
| Loop Powered |
CTX-ACR-3S & 4S High AC Current Transmitters
|
| True RMS 0-375 Amps to 0-2000 Amps AC
| Isolated Output 4-20 mA
| Loop Powered |
CTX-DC DC Current Transmitters
|
| 0-50 Amps to 0-400 Amps DC
| Isolated Output 4-20 mA
| 20-50 VDC or 22-38 VAC |
CS-AC
AC Current Switches
|
| 1.5-150 Amps AC
| 0.15 Amp SSR LED Status Indicator NC or NO Models
| Self Powered |
CS-DC
DC Current Switches
|
| 5-100 Amps DC
| 0.3 Amp SSR or 5 Amp Relay LED Status Indicator
| 20-28 VAC/VDC or 12 VAC/VDC LED Power Indicator |
2RL/5RL/7RL/8RL
AC Current Transformers
|
| 600 VAC 50:5 to 1600:5 Ratios
| Proportional to Input
| Self Powered |