Cecomp
Electronics
|
| Battery
Powered Digital Pressure Gauges
|
| DPG1000B
& DPG1000BBL Digital Pressure Gauge
Battery Powered & Battery Powered w. Backlit Display
- Ideal for portable applications
- Up to 2500 hour battery life (less with
backlighting)
- 500 hour battery life with 3000 and 5000
psi ranges
(less with backlighting)
- Auto shutoff standard
- On/Off button in ranges up to 1999

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
- Choose auto shutoff time
-5 five minutes
-10 ten minutes
-30 thirty minutes
-ON on/off only
|
|
F4B
& F4BBL Digital Pressure Gauge
NEMA 4X Battery Powered &
Battery Powered w. Backlit Display
- Water resistant housing
- Ideal for portable & process applications
- Up to 2500 hour battery life (less with
backlighting)
- Auto shutoff standard
- On/Off button in ranges up to 1999

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
- Choose auto shutoff time
-5 five minutes
-10 ten minutes
-30 thirty minutes
-ON on/off only
|
| ARM760B,
ARM760BBL Digital Pressure Gauge
Battery Powered Digital Vacuum Gauges 760 Torr Absolute
- Battery
life to 2500 hrs
- BL
red LED display backlight battery life to 180 hrs
- 5
minute auto shutoff
- Front
zero and span potentiometers
- ±0.25%
test gauge accuracy
- 316
stainless steel sensor
- Includes
2 AA batteries

Back To Top
|
The ARM 760 series is pre-configured for 760 Torr absolute.
It reads atmospheric pressure with no connection and zero
at full vacuum.
- Ideal for vacuum packaging applications
- Replace laboratory mercury manometers and mercury vacuum
gauges
|
|
Digi Max® F16B, F16BBL,
NEMA4X F16NB,
F16NBBL
Battery Powered, Min/Max/Zero
Nema 4X & Backlit models
- Capture minimum and maximum readings
- Push button zero
- 4 digit display
- Battery life to 2000 hrs
- BL red LED display backlight battery life 150 to 1500
hrs
- Internal calibration buttons
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy in most ranges
- 316 stainless steel sensor
- Includes 2 AA batteries

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
- Choose auto shutoff time
-5 five minutes
-10 ten minutes
-30 thirty minutes
-ON on/off only
- Special - seconds, minutes, or hours
|

|
Digi Max® F18B, F18BBL,
NEMA4X F18BN,
F18BNBL
Battery Powered Digital Pressure
Gauges with Min/Max/Zero, Selectable Units, Selectable Shutoff
- Capture minimum and maximum readings
- 4 digit display
- Battery life to 2000 hrs
- BL red LED display backlight battery life 150 to 1500
hrs
- Internal buttons for units, shutoff time, calibration
for better tamper-resistance
- Pass code protected calibration
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy in most ranges
- 316 stainless steel sensor
- Includes 2 AA batteries

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- Slectable engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2 depending on range
- Selectable auto shutoff time
|

|
Digi Max® F20B, F20BBL,
NEMA 4X F20BN,
F20BNBL
Battery Powered Digital Pressure
Gauges with Memory, Zero, Selectable Units, Selectable Shutoff
- Capture 4 or 6 maximum readings
- 4 digit display
- Battery life to 2000 hrs
- BL red LED display backlight battery life 150 to 1500
hrs
- Keypad for units, shutoff time, calibration
- Pass code protected calibration
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy in most ranges
- 316 stainless steel sensor
- Includes 2 AA batteries

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- Slectable engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2 depending on range
- Selectable auto shutoff time
|

|
RB
Rubber Boot
- Orange molded rubber
- Protects gauge appearance
- For standard housings only. Does not fit NEMA 4X models

Back To Top
|
- Order item RB as a separate line item on your order
|

| CD
Calibration Data
NC
NIST Traceable Calibration Data
- 5 calibration points
- Test data
- Gauge model & serial number
- Date of test
- NC includes information on the NIST traceable calibration
standard used

Back To Top
|
|
| Low
Voltage AC/DC Powered Digital Pressure Gauges
|
| DPG1000AD
& DPG1000ADBL Digital Pressure Gauge
AC/DC Powered
& AC/DC Powered w. Backlit Display
- Powered by 8-24 VAC 50/60 Hz or 9-32 VDC
- 3-1/2 digit display
- Front zero and span potentiometers
- ADBL has red LED display backlight
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy (most ranges)
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
|
| F4AD
& F4ADBL
Digital Pressure Gauge
NEMA 4X AC/DC Powered
& AC/DC Powered w. Backlit Display
- NEMA 4X housing
- 3-1/2 digit display
- Front zero and span potentiometers
- ADBL has red LED display backlight
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy (most ranges)
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
|
|
Digi
Max® F16AD, F16ADBL F16NAD, F16NADBL
Low voltage AC/DC Powered,
Min/Max/Zero,
Nema 4X & Backlit models
- Capture minimum and maximum readings
- Push button zero
- 4 digit display
- Internal calibration buttons
- ADBL has red LED display backlight
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy (most ranges)
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
|
| Digi
Max®
F16ADN, F16ADNBL
NEMA 4X Low Voltage Powered Digital
Pressure Gauges with Min/Max, Push Button Zero
- NEMA 4X housing
- Capture minimum and maximum readings
- Push button zero
- 4 digit display
- Internal calibration buttons
- ADNBL has red LED display backlight
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy (most ranges)
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
|

| ARM760
Series Digital Pressure Gauge
Digital Manometers, 760 Torr
Absolute
- Includes AC adapter
- Front zero and span potentiometers
- ADBL has red LED display backlight
- ±0.25% test gauge accuracy
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
The ARM 760 series is pre-configured for 760 Torr absolute.
It reads atmospheric pressure with no connection and zero
at full vacuum.
- Ideal for vacuum pump monitoring
- Replace laboratory mercury manometers and mercury vacuum
gauges
|
|
Digital
Pressure Gauge/Transmitters - Low Voltage & Loop Powered
|
| DPG1000L
Digital Pressure Gauge
4-20mA Current Loop Powered
- 2-wire 4-20mA loop powered indicating
transmitter
- True analog output (not digitized)
- TEST button to check operation of output
- Powered by 9-32 VDC current loop

Back To Top
|
- 4-20 mA passive transmitter
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
|
| F4L
Digital Pressure Gauge
NEMA 4X 4-20mA
Current Loop Powered
- Water resistant housing
- 2-wire 4-20mA loop powered indicating
transmitter
- True analog output (not digitized)
- TEST button to check operation of output

Back To Top
|
- 4-20 mA passive transmitter
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
|
| F4DR
& F4DRBL Digital Pressure Gauge
NEMA 4X AC/DC
Powered with Analog Output
- Water resistant housing
- True analog 4-20 mA or 0-2 volt output
(not digitized)
- TEST button to check operation of output
- Powered by 8-24 VAC or 9-32 VDC
- 4-20 mA version powers current loop

Back To Top
|
- 4-20 mA passive transmitter
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
|
| Loop-Powered
2-Wire Indicating Transmitters
|

| F16L
Digital Indicating Pressure Transmitter
Programmable 2-Wire, 4-20 mA, Loop Powered
- 2-wire loop powered
- 4-20mA output
- Programmable output range
- 4 digit display
- Internal calibration buttons
- Output test button
- Adjustable output test
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy in most ranges
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- 4-20 mA passive transmitter
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
|

| F16LN
Digital Indicating Pressure Transmitter
NEMA 4X Programmable 2-Wire, 4-20 mA,
Loop Powered
- 2-wire loop powered
- 4-20mA output
- Programmable output range
- 4 digit display
- Internal calibration buttons
- Output test button
- Adjustable output test
- NEMA 4X housing
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy in most ranges
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- 4-20 mA passive transmitter
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
|
| DPG1000DR
& DPG1000DRBL
Digital
Pressure Gauge
AC/DC Powered with
Analog Output
- True analog 4-20 mA or 0-2 volt output
(not digitized)
- TEST button to check operation of output
- Powered by 8-24 VAC or 9-32 VDC
- 4-20 mA version powers current loop
- DPG1000DRBL has backlit display

Back To Top
|
- 4-20 mA passive transmitter
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
|
| Pressure
To Current Converters
|
| DPG1000L3-15PSIG
Pressure to Current Converter
P/I converter for converting
a pneumatic control
signal to 4-20mA
- 2-wire 4-20mA loop-powered
- 3-1/2 digit display
- Front zero and span potentiometers
- Adjustable output test
- ±0.25% test gauge accuracy
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- 3.00 to 15.00 psig
- Factory configured
|
| F4L3-15PSIG
Pressure to Current Converter, NEMA 4X
P/I converter for
converting a pneumatic control
signal to 4-20mA
- NEMA 4X housing
- 3.00 to 15.00 psig
- Factory configured
- 2-wire 4-20mA loop-powered
- 3-1/2 digit display
- Front zero and span potentiometers
- Adjustable output test
- ±0.25% test gauge accuracy
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- 3.00 to 15.00 psig
- Factory configured
|
| F16L3-15PSIG
Programmable
Pressure to Current Converter
P/I
converter for converting a pneumatic control
signal
to 4-20mA
- Programmable output
- 2-wire 4-20mA loop-powered
- 4 digit display
- Internal calibration buttons
- Adjustable output test
- ±0.25% test gauge accuracy
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
|
| F16LN3-15PSIG
Programmable
Pressure to Current Converter
NEMA 4X
P/I
converter for converting a pneumatic control
signal
to 4-20mA
- NEMA 4X housing
- Programmable output
- 2-wire 4-20mA loop-powered
- 4 digit display
- Internal calibration buttons
- Adjustable output test
- ±0.25% test gauge accuracy
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
|
|
Digital
Pressure Gauge/Switches
|
| DPG1000ADA
Digital Pressure Gauge
Dual SPDT Alarm Relays
- Two pilot duty 0.5 amp@115VAC (1A@24VDC)
alarm relays
- User adjustable setpoints
- TEST button to check operation of alarms
- Powered by 8-24 VAC or 9-32 VDC

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
- Choose alarm configuration
-1N Hi/Lo Normal
-2N Hi/Hi Normal
-3N Lo/Lo Normal
-1R Hi/Lo Reverse
-2R Hi/Hi Reverse
-3R Lo/Lo Reverse
|

| F16ADA,
F16ADABL, F16ADAN, F16ADANBL
Low Voltage
Powered Digital Pressure Gauges
with
Two SPDT Programmable Alarm Relays
BL
= backlit display
N
= NEMA 4X
- Two SPDT relays
- 1% hysteresis
- LED alarm indicators
- Keypad setup and calibration
- ADABL has red LED display backlight
- 4 digit display
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy in most ranges
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
- Choose alarm configuration
-1N Hi/Lo Normal
-2N Hi/Hi Normal
-3N Lo/Lo Normal
-1R Hi/Lo Reverse
-2R Hi/Hi Reverse
-3R Lo/Lo Reverse
|

| F16ADAH,
F16ADAHBL, F16ADAHN, F16ADAHNBL
Low Voltage Powered Digital Pressure Gauges with
Programmable Trip/Reset DPDT Alarm Relay
BL = backlit display
N = NEMA 4X
- DPDT relay
- Programmable trip and reset points
- LED alarm indicators
- ADAHBL has red LED display backlight
- 4 digit display
- ±0.25% test gauge accuracy
- Optional ±0.1% accuracy in most ranges
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
- Choose alarm configuration
-NT Normal, tripped at power up in deadband
-NR Normal, not tripped at power up in deadband
-RT Reverse, tripped at power up in deadband
-RR Reverse, tripped at power up in deadband
|
| DPG1000DAR
Digital Pressure Gauge
Dual SPDT
Relays and Analog Output
- Two pilot duty 0.5 amp@115VAC (1A@24VDC)
alarm relays
- User adjustable setpoints
- True analog 4-20 mA or 0-2 volt output
(not digitized)
- TEST button to check operation of output
and alarms
- Powered by 8-24 VAC or 9-32 VDC
- 4-20 mA version powers current loop

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
- Choose alarm configuration
-1N Hi/Lo Norma
-2N Hi/Hi Normal
-3N Lo/Lo Normal
-1R Hi/Lo Reverse
-2R Hi/Hi Reverse
-3R Lo/Lo Reverse
- Choose analog output type
-V for 0-2 volt
-I for 4-20 mA
|

| F16DAR,
F16DARBL, F16DARN, F16DARNBL
Low
Voltage Powered Digital Pressure Gauges with Two Programmable
SPDT Alarm Relays and Programmable Analog Output
BL = backlit display
N = NEMA 4X
- Two programmable SPDT alarm
relays
- Programmable alarm types
- Programmable analog output
range
- Programmable hysteresis
- LED alarm indicators
- Front buttons for setpoints
and calibration
- 4 digit display
- Output test function for
analog output and relays
- Programmable analog output
test
- Choose 0-2V or 4-20mA analog
output
- mA output powers current
loop
- ±0.25% test gauge
accuracy
- Optional ±0.1% accuracy
in most ranges
- 316 stainless steel sensor
- 7-10 day typical lead time
- 1 year warranty

Back To Top
|
- Vacuum to 5000 psi ranges
- Absolute reference available
- All common engineering units available: psi, inHg, oz/in2,
inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar,
kPa, MPa, atm, kg/cm2, custom
- Choose analog output type
-V for 0-2 volt
-BV for ±2 volt output when ordered with bipolar
range
-I for 4-20 mA
|
|
Digital Indicating Temperature Transmitters
|
|
F4LT-Series
ThermoPro®
Indicating Temperature Transmitters

Back To Top
|
|

|
T16B
Series
ThermoPro®
Battery Powered
RTD Temperature Indicator
Input
Specify RTD Length
and Fixed or Spring-Loaded RTD
Temperature Range
58.0°F
to 392.0°F or
50.0°C
to 200.0°C
Selectable °F
or °C
See data sheet
for model numbers

Back To Top
|
- 0.1 Degree Display Resolution
- Precision RTD Element
- NEMA 4X Housing
- Powered by Two AA batteries
(included)
- 316 Stainless Steel Probe
- 1/2" NPT Fitting for
Standard Thermowells
- Spring-Loaded Probe for
use with Thermowells
|

| T16L
Series (F16LT)
ThermoPro®
Indicating RTD Transmitter
Input
Specify RTD Length
and Fixed or Spring-Loaded RTD
Temperature Range
58.0°F to 392.0°F or
50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
Output
4-20 mA Output
is User Configurable Over the Temperature Range

Back To Top
|
- User-Programmable 4-20 mA
Output Range
- 0.1 Degree Display Resolution
- Precision RTD Element
- NEMA 4X Housing
- 2-Wire Design
- Powered by 8-32 VDC 4-20
mA Current Loop
- 316 Stainless Steel Probe
- 1/2" NPT Fitting for
Standard Thermowells
- Spring-Loaded Probe for
use with Thermowells
|

|
T16ADA
Series
ThermoPro®
Indicating RTD Alarm
Input
Specify RTD Length
and Fixed or Spring-Loaded RTD
Temperature Range
58.0°F to 392.0°F or
50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
Output
2 SPDT relays,
1 A @ 24 VDC,
0.5 A @ 115 VAC,
Non-inductive,
Fully programmable

Back To Top
|
- User-Programmable Alarm
Relays
- 0.1 Degree Display Resolution
- Precision RTD Element
- NEMA 4X Housing
- Powered by 8-32 VDC, 10-32
VAC
- 316 Stainless Steel Probe
- 1/2" NPT Fitting for
Standard Thermowells
- Spring-Loaded Probe for
use with Thermowells
|
|
Tech
Information, Ranges, Accessories & Options
|

Back
To Top
|
Tech
Info, Ranges
Accessories
& Options
NEW!
Pressure
Units Converter
- Alarm & Retransmission Data
- Optional 0.1% Accuracy
- Optional NIST Traceability
- Protective Rubber Boot
- Panel Mounting
- Extended Temperature Display
- Conformal Coating
|
|
| Cecomp
Model Comparison Chart |
| Model |
Power |
Ranges |
NEMA
4X |
Backlit
Display |
Min/Max
Zero |
Analog
Output |
Alarms |
| Battery Powered
Digital Pressure Gauges |
| F16B |
Battery |
Vac to 5000 psi |
|
|
Yes |
|
|
| F16BBL |
Battery |
Vac to 5000 psi |
|
Yes |
Yes |
|
|
| F16NB |
Battery |
Vac to 5000 psi |
Yes |
|
Yes |
|
|
| F16NBBL
|
Battery |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F18NB |
Battery |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F18NBBl |
Battery |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F18BN |
Battery |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F18BNBl |
Battery |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F20NB |
Battery |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F20NBBl |
Battery |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F20BN |
Battery |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F20BNBl |
Battery |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F4B |
Battery |
Vac to 5000 psi |
Yes |
|
|
|
|
| F4BBL
|
Battery |
Vac to 5000 psi |
Yes |
Yes |
|
|
|
| DPG1000B |
Battery |
Vac to 5000 psi |
|
|
|
|
|
| DPG1000BBL |
Battery |
Vac to 5000 psi |
|
Yes |
|
|
|
| ARM760B |
Battery |
760 Torr absolute |
|
|
|
|
|
| ARM760BBL |
Battery |
760 Torr absolute |
|
Yes |
|
|
|
| Low Voltage Powered
Digital Pressure Gauges |
| F16AD |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
|
|
Yes |
|
|
| F16ADBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
|
Yes |
Yes |
|
|
| F16ADN |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F16ADNBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F16NAD |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
|
Yes |
|
|
| F16NADBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
Yes |
|
|
| F4AD
|
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
|
|
|
|
| F4ADBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
|
|
| F4ADN |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
|
|
| F4ADNBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
|
|
| DPG1000AD |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
|
|
|
|
|
| DPG1000ADBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
|
Yes |
|
|
|
| ARM760AD |
8-24 VAC or 9-32 VDC* |
760 Torr absolute |
|
|
|
|
|
| ARM760ADBL |
8-24 VAC or 9-32 VDC* |
760 Torr absolute |
|
Yes |
|
|
|
| Loop Powered
& Low Voltage Powered Digital Pressure Gauge/Transmitters |
| F4L |
8-32 VDC Current Loop |
Vac to 5000 psi |
Yes |
|
|
4-20 mA |
|
| DPG1000L |
8-32 VDC Current Loop |
Vac to 5000 psi |
|
|
|
4-20 mA |
|
| F4DR
|
8-24 VAC or 9-32 VDC |
Vac to 1999 psi |
Yes |
|
|
4-20 mA or 0-2 V |
|
| F4DRBL |
8-24 VAC or 9-32 VDC |
Vac to 1999 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
|
| F16L |
Loop Powered |
Vac to 5000 psi |
|
Yes |
|
4-20 mA or 0-2 V |
|
| F16LN |
Loop Powered |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
|
| DPG1000DR |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
|
|
|
4-20 mA or 0-2 V |
|
| DPG1000DRBL |
8-24 VAC or 9-32 VDC |
Vac to 1999 psi |
|
Yes |
|
4-20 mA or 0-2 V |
|
| DPG1000DAR |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
|
|
|
4-20 mA or 0-2 V |
2 SPDT |
| Low Voltage Powered
Digital Pressure Gauge/Switches |
| DPG1000ADA |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
|
|
|
|
2 SPDT ✓ |
| DPG1000DAR |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
|
|
|
4-20 mA or 0-2 V |
2 SPDT |
| F16ADA |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
2 SPDT |
| F16ADABL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
2 SPDT |
| F16ADAN |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
2 SPDT |
| F16ADNBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
2 SPDT |
| F16ADAH |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
1 SPDT |
| F16ADAHBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
1 SPDT |
| F16ADAHN |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
1 SPDT |
| F16ADAHNBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
1 SPDT |
| F16DAR |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
2SPDT |
| F16DARBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
2 SPDT |
| F16DARN |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
2 SPDT |
| F16DARNBL |
8-24 VAC or 9-32 VDC |
Vac to 5000 psi |
Yes |
Yes |
|
4-20 mA or 0-2 V |
2 SPDT |
|
Back
To Top |
|