Dynalco Speed Switches and Transmitters are available in several versions including magnetic pickup powered. Some have proportional outputs for remote reading or powering external devices.
Speed Switch/Transmitter Comparison Chart
NEW!SW-100 Speed Switch
The SW-100 has a single setpoint for over/
underspeed protection. It mounts on a DIN rail and has a simple configuration - no test
equipment or computer needed.
Features:
- Accepts frequency input and controls a single
relay (SPDT) for over/under speed trip
- Relay configurable for non-latching or latching
with external alarm override and reset
- Relay contacts rated 5A @ 120/240VAC or
28VDC (resistive)
- LED indicators for input signal and relay status
- Calibrate with or without input signal
- Signal input DIP switch selectable to accept
switch contacts, mag pickups, CMOS or TTL
circuits
- 9-32VDC or 85-250VAC power supply
- 0.1Hz - 25KHz operating frequency range
- Accuracy 0.1% for setpoints
NEW! SWT-1000 / SWTD-1000
Speed Switch/Transmitter with Optional Display
The SWT-1000 and SWTD-1000 have a Single relay setpoint for over
speed protection and 4-20mA isolated output. Configurable via Windows® based
software.
Features:
- Converts frequency to an analog signal
- Output configurable for 4-20 mA or 0-10 VDC
- 0Hz - 50kHz operating frequency range
- Integrated backlit display (SWTD-1000)
- 2 possible relay set-point configuration sets
(A & B) for start up / run, controlled via binary inputs
- Open pickup sensor warns against failed pickup
- Plug in terminals for easy installation
- Isolated signal input with automatic trigger level
adjustment ensures accurate speed measurement
- Open collector repeater output provides signal to
external devices
- Accuracy 0.05% for setpoints, 0.5% for analog signals
- Fast response to over-speed conditions, 10.5ms typical
- Adaptive input signal sensitivity provides high noise
immunity
- Integrated 2 or 3 wire sensor monitoring and
system watchdog
NEW! SWT-2000
2 Channel Speed Switch/Transmitter
2 Speed switches in one. Monitor and protect two
separate machines or provide redundant speed
protection on one machine. Allows multiple setup
configurations. DIN rail mounting.
Features:
- 2 frequency + 2 binary inputs
- 2 current (4-20 mA) outputs
- 4 relay and 2 open collector outputs
- Open pickup sensor
- 4 parameter sets each with 6 set-points for
almost limitless applications
- x1, x2 or x4 repeater outputs
- Fully isolated I/O
- High accuracy speed measurement: 0.002% for
set-points and 0.1% for analog signals
- Programmable logical, diagnostic and
measurement functions
- Fast 8 ms reaction time on overspeed
- Compatible with passive and active mag pickups
- Plug in terminals
- 18-36 VDC or 90-264 VAC power supply
- Ethernet interface - configuration via Windows®
software
- 0Hz - 50kHz operating frequency range
SST-2000A and SST-2000H Series Speed Switch/Transmitter
SST-2000A and SST-2000H Series Speed Switches/Transmitters receive signal input from a passive or active magnetic pickup, shaft encoder, contact closure, flowmeter, etc., to provide proportional analog outputs and either 0, 2, or 4 relay trip setpoints.
Features:
- The ultimate in Over/Under Speed Protection for your rotating equipment
- The SST-2000A/H Series Speed Switch/Transmitter is available in six variations:
Model |
No. of Setpoints |
Analog Outputs |
3rd Party Certifications |
SST-2000A |
0 |
2 Analog Ouptuts: 1) 0-1 mA Ouput 2) 4-20 mA Ouput or 0-5 VDC or 0-10 VDC (switch selectable)
|
CSA: General Certification LR 92270 ABS: type approval CE: 89/336/EEC, Light Industrial CE: 72/23/EEC, Low Voltage Directive |
SST-2200A |
2 |
SST-2400A |
4 |
SST-2000H |
0 |
2 Analog Ouptuts: 1) 0-1 mA Ouput 2) 4-20 mA Ouput or 0-5 VDC or 0-10 VDC (switch selectable) |
CSA: Class I, Div. 2, Grp. D, LR 45322* CE: 89/336/EEC, Light Industrial CE: 72/23/EEC, Low Voltage Directive |
SST-2200H |
2 |
SST-2400H |
4 |
|
* Approval contingent upon housing an SST-2000H series device in a CSA-certified enclosure.
|
SW-200B Speed Switch
The SW-200B provides reliable engine overspeed protection. It has three adjustable relay setpoints: number one is overspeed. Uses for the two auxiliaries include crank disconnect, generator field-flashing, and speed monitoring. Setpoints are field-programmable and can be tested without overspeeding. Housing is gasketed and sealed.
Features:
- over/under speed protection
- crank disconnect
- speed monitoring
- transmitter
- 3 relay setpoints
SW-50 Speed Switch
The SW-50 Speed Switch provides reliable engine overspeed protection and is fully field- programmable. The SW-50 Speed Switch has two relay setpoints: one overspeed plus one auxiliary for crank disconnect, generator field-flashing, or other alarm.
Features:
- overspeed protection
- alarm
- 2 relay setpoints
F-16 Signal Generator/Counter/Calibrator
Used to calibrate tachometers, digital speed indicators, governors, counters, frequency meters. Measures signal frequency from magnetic pickups, pulsers, ac generators, shaft encoders. Eliminates the need for a frequency counter or an audio generator.
|