Dynalco TMP-100DC 24VDC Powered Digital Indicator with 18 Channels

The Dynalco TMP-100DC 18-channel temperature indicator accepts grounded and ungrounded thermocouples of the same type, depending on the model. Integral cold junction compensation. Some versions accept all 100 ohm platinum RTDs. Not intrinsically safe. Uses 24 Vdc power.

TMP-100DC Multi-Point Digital Pyrometer from Dynalco Controls

 

 

 

 

 

 

 

Dynalco TMP-100DC Multi-Point Digital Pyrometer

FEATURES:

  • 24VDC Powered
  • Digital readout with 1º resolution
  • Heavily gold-plated selector switch for long life, trouble-free operation
  • Integral 2-pole selector switch permits using grounded or ungrounded thermocouples.
  • Fits existing cutouts and mounting holes of other popular pyrometers
  • Compensation for lead lengths or lead resistances not required; use inexpensive small gauge thermocouple extension wire and save cost and
    space
  • Fully gasketed; rugged construction.
  • Readout unaffected by power line noise and spikes
  • Continuous readout
  • 2 year warranty
  • Also available with 24 Channels is the new TMP-200DC
TMP-100DC
Back to Dynalco Temperature Indicators

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS  
Display: 3-1/2 digit (–999 to +1999), 0.5" high,
liquid crystal display, 1º increment. Brightness
increases with ambient light (no outdoors fadeout).
- Open thermocouple or RTD indicated by a
number 1 in the thousands column; all other
digits blanked.
- Momentarily pressing the front display push
button activates the display for 50 seconds.
Environment Temperature: 0ºF to +165ºF
(–18ºC to +74ºC); 0.25% maximum effect on readout.
Selector Switch: Two-pole, 19-position, double
gold plating of contacts.

Sensor:
Thermocouples:
Grounded or ungrounded; MUST BE GROUNDED IF DC SUPPLY IS GROUNDED
integral cold junction compensation.
Thermocouple extension wire resistance of up to
100Ω introduces less than 1º error.
RTDs:
Accepts 2-wire RTDs only. Use with heavy
copper extension leads to minimize error, i.e., 16
AWG for up to 50 feet, 14 AWG to 100 feet.
Power:
24 Volt dc systems; 6 mA dc typical, 10 mA
maximum
Weight: 1.75 lbs

PART NUMBERS AND RANGES
PART NUMBER RANGE SENSOR TYPE
TMP-100DC-11 -50º to +1500ºF J (Iron-Constantan)
TMP-100DC-12 -45º to +815ºC J (Iron-Constantan)
TMP-100DC-13 -50º to +1800ºF K (Iron-Alumel)
TMP-100DC-14 -45º to +980ºC K (Iron-Alumel)
TMP-100DC-15 0º to +500ºF T (Copper-Constantan)
TMP-100DC-16 -20º to +260ºC T (Copper-Constantan)
TMP-100DC-17 0º to +500ºF E (Chromel-Constantan)
TMP-100DC-18 -20º to +260ºC E (Chromel-Constantan)
TMP-100DC-19 -300º to +800ºF 100 Ohm Pt RTD
TMP-100DC-20 -185º to +425ºC 100 Ohm Pt RTD