AGL Series Ground Fault Relays


AGL large-aperture ground-fault relays monitor AC earth leakage through a 1.76 in (44.7 mm) maximum wire bundle. Select an SPDT auto-reset relay or N.O./N.C. SPST latching relay, factory-set or tri-set trip points, and standard or noise-immunity construction.


Select & Configure Model
Base Model #Case StyleSetpoint RangeSensing Aperature SizeResponse TimeOutput Types / RatingsNormally
In Stock
Add to Cart /
Configure Part #
 
AGL1Solid Core5–100 mA factory set1.76 in (44.7 mm)150 ms at 5%, 100 ms at 50%, 50 ms at 500% above setpointMechanical relay; standardInquireConfigurator
AGL2Solid Core80–950 mA factory set1.76 in (44.7 mm)150 ms at 5%, 100 ms at 50%, 50 ms at 500% above setpointMechanical relay; standardInquireConfigurator
AGL3Solid Core5/10/30 mA jumper-selectable1.76 in (44.7 mm)150 ms at 5%, 100 ms at 50%, 50 ms at 500% above setpointMechanical relay; standardInquireConfigurator
AGL1Solid Core5–100 mA factory set1.76 in (44.7 mm)150 ms at 5%, 100 ms at 50%, 50 ms at 500% above setpointMechanical relay; noise immunity (-N)InquireConfigurator
AGL2Solid Core80–950 mA factory set1.76 in (44.7 mm)150 ms at 5%, 100 ms at 50%, 50 ms at 500% above setpointMechanical relay; noise immunity (-N)InquireConfigurator
AGL3Solid Core5/10/30 mA jumper-selectable1.76 in (44.7 mm)150 ms at 5%, 100 ms at 50%, 50 ms at 500% above setpointMechanical relay; noise immunity (-N)InquireConfigurator
Power Supply:

120 V AC (66–132 V) or 24 V AC/DC (19–29 V)

Setpoint range:

AGL1: 5–100 mA; AGL2: 80–950 mA factory set; AGL3: 5/10/30 mA jumper-selectable

Output Ratings:

1 A at 120 V AC; 2 A at 30 V DC resistive

Time Delay:

None

Frequency Range:

50–60 Hz

Environmental:

−20 to 50°C; 0–95% RH, non-condensing

Maximum Wire Bundle Diameter:

1.76 in (44.7 mm)

Power Consumption:

2.5 VA

Output(s):

SPDT auto-reset relay or N.O./N.C. SPST latching relay

Response Time:

150 ms at 5%, 100 ms at 50%, 50 ms at 500% above setpoint

Isolation Voltage:

2200 V AC

Case:

Solid-core; UL94 V-0 flammability-rated housing

Approvals:

UL/cUL Listed to UL 508 (E129625), CE


AGL1 factory setpoints cover 005–100 mA, AGL2 covers 080–950 mA, and AGL3 provides 5/10/30 mA jumper selection. NOR1/NCR1 relay outputs require LA latching; SDT1 requires DEN or ENE auto-reset. Supply choices are 120 V AC and 24 V AC/DC. Example: AGL1-NOR1-120-LA-005.

Pass all current-carrying conductors of the monitored circuit through the sensing window. Follow the installation sheet for conductor arrangement, grounding and external trip-device wiring. The sensor provides a detection/contact signal; use it as part of a suitable protection system.


Mod Tronic Instruments Limited
1 Delta Park Blvd #12
Brampton, ON L6T 5G1
Phone: 905-457-6322 or 1-800-794-5883
Fax: 905-457-4716 or 1-800-830-7122
Brampton
Halifax
Regina
Edmonton
905-457-6322
902-422-0978
306-359-1476
780-459-2690
Montreal
Winnipeg
Calgary
Vancouver
514-848-7205
204-895-2038
403-236-2909
604-224-9547