| Acuvim 3 Series Advanced Power Quality Meters |  | Accuenergy | 400 VAC L-N; 690 VAC L-L (+20%) | 5A/1A or 333 mV/Rogowski | P1: 100-415 VAC / 100-300 VDC; P2: 20-60 VDC | Digital / relay I/O; optional modules |  | Compare |
| SIRAX BM1200, BM1400, BT5700, MM1200, MM1400, Programmable, Multifunctional Monitors |  | Camille Bauer | 110 -500 VL-L , 10 - 1000 VDC | 1 - 5 A, 50 - 150mV | 12 - 48 V DC, 60 - 300 V AC/DC | RS485, 2 x 4…20 mA analog, Ethernet |  | Compare |
| SIRAX MT7000/MT7050 & MT7100/MT7150 Series Power & Energy Meters |  | Camille Bauer | ±10 Vpk or ±1 Vpk, 300 VLN / 500 VLL | 1A / 5A | 10 - 30 VDC or 19 - 28 VAC (50/60 Hz) | RS485 Modbus/RTU, 0 - 10 V or 4 - 20 mA |  | Compare |
| SINEAX A210, A220, A230S, A230 Multifunctional Power Monitor |  | Camille Bauer | Phase-phase: 500 V, Phase-N: 290 V | 1A / 5A | 24 - 60 V AC/DC, 100 - 230 V AC/DC | RS232/RS485 |  | Compare |
| APLUS Multifunctional Power Monitor |  | Camille Bauer | 12 / 24 V DC (30 V max.) | 1A / 5A | 100 - 230 V AC, 50 - 400 Hz | RS485 Modbus/RTU, Ethernet Modbus/TCP |  | Compare |
| SINEAX AM1000, AM2000, AM3000 Multifunctional Power Monitor |  | Camille Bauer | 57.7 - 693 VLL | 1A / 5A | 100 - 230 V AC/DC, 24 - 48 V DC | Upto 4 Digital/Analog Output |  | Compare |
| LINAX PQ3000 & PQ5000, Multifunctional Power Quality Monitor |  | Camille Bauer | 57.7 - 693 VLL | 1A / 5A | 100 - 230 V AC/DC, 24 - 48 V DC | Upto 4 Digital/Analog Output |  | Compare |
| AcuRev 2100 Series Multi-Circuit Power and Energy Submeters |  | Accuenergy | 400 VAC L-N; 690 VAC L-L | 18 inputs: 80/100 mA or 333 mV/Rogowski | 100-415 VAC / 100-300 VDC | 18 DI / 2 RO; WEB2 networking |  | Compare |
| CENTRAX CU3000, Power Measurement Device (PLC) |  | Camille Bauer | 57.7 - 693 VLL | 1 / 5 A | 100 - 230 V AC/DC, 24 - 48 V DC | Upto 4 Digital/Analog Output |  | Compare |
| Acuvim II Series Power and Energy Meters |  | Accuenergy | 480 VAC L-N; 828 VAC L-L | 5A/1A; 80/100/200 mA; mV/Rogowski | P1V3: 100-415 VAC / 100-300 VDC; P2V3: 20-60 VDC | Optional digital / analog / relay modules |  | Compare |
| Acuvim IIBN BACnet Series Power and Energy Meters |  | Accuenergy | 400 VAC L-N; 690 VAC L-L | 5A/1A; mA; 333 mV; Rogowski | P1: 100-415 VAC / 100-300 VDC; P2: 20-60 VDC | BACnet MS/TP; RS485 |  | Compare |
| Acuvim L Series Power and Energy Meters |  | Accuenergy | 480 VAC L-N; 828 VAC L-L | 5A/1A or mV/Rogowski | P1V4: 100-415 VAC / 100-300 VDC; P2V4: 20-60 VDC | Optional digital / analog / relay modules |  | Compare |
| AcuRev 1320 Series DIN Rail Power and Energy Meters |  | Accuenergy | 69-480 VAC L-N; 830 VAC L-L | 80/100 mA or 333 mV/Rogowski | 100-300 VAC CAT III; 100-480 VAC CAT II | 3 DI / 1 DO; RS485; dual Ethernet |  | Compare |
| EV300 Series Multifunction Power and Energy Meters |  | Accuenergy | 230 VAC L-N; 400 VAC L-L (+20%) | 5A/1A CT input | 100-240 VAC / 100-300 VDC | E0-E4 digital / analog / relay options |  | Compare |
| AcuDC-261 MID Dual Port EV Charging Meters |  | Accuenergy | 60-1000 VDC | 400 A or 600 A external shunt | 12-48 VDC SELV | RS485 / Ethernet Modbus |  | Compare |
| AcuDC-262 Advanced DC Power and Energy Meters |  | Accuenergy | 12-1000 VDC | 0-100 mV / 4-20 mA / -5 to +5 V | 12-48 VDC SELV | RS485 / Ethernet Modbus |  | Compare |
| AcuRev 2000 Multi-Circuit Power and Energy Meters — Discontinued |  | Accuenergy | 400 VAC L-N / 690 VAC L-L nominal | 333 mV CT or Rogowski input; external CT ratio | 100-415 VAC / 100-300 VDC | Legacy RS485; optional WEB communications |  | Compare |
| AcuRev 1310 Series DIN Rail Power and Energy Meters |  | Accuenergy | 400 VAC L-N; 690 VAC L-L | 5A/1A; mA; 333 mV; Rogowski, by model | 100-415 VAC / 100-300 VDC | Modbus RTU; BACnet MS/TP; optional relay |  | Compare |
| AcuDC 300 Series EV Charging Meters |  | Accuenergy | 60-1000 VDC | 650 A built-in shunt | 24 VDC | RS485; signed OCMF data |  | Compare |
| AcuDC 240 Series DC Power and Energy Meters |  | Accuenergy | Up to 1000 VDC direct; external sensor options | Direct ±10 A or external shunt/Hall sensor | P1: 100-240 VAC / 100-300 VDC; P2: 20-60 VDC | Optional DI / DO / AO / RO; RS485 |  | Compare |
| AcuRev 4100 Series Multi-Channel Branch Circuit Submeters |  | Accuenergy | 60-480 VAC L-N; 830 VAC L-L | 24 inputs: mA or mV/Rogowski | 100-300 VAC CAT III; 100-480 VAC CAT II | 4 DI / 8 DO / 2 RO; RS485; Ethernet |  | Compare |
| AcuPanel 9100 Series Pre-Wired Power and Energy Meter Panels |  | Accuenergy | Up to 400 VAC L-N / 690 VAC L-L; meter dependent | 5A/1A, mA or mV/Rogowski; model dependent | P1/P2/P3/P4; meter-specific ratings | RS485; optional networking and I/O |  | Compare |