KINAX N702-INOX HART Absolute Inclination Transmitter


The KINAX N702-INOX HART from Camille Bauer measures absolute inclination in wet or corrosive locations. Its sealed stainless-steel housing and PUR-sheathed signal cable suit applications exposed to seawater or detergents.

  • Use the HART interface for parameterization.
  • Select the model by its measuring range and cable configuration.
  • Choose compatible mounting clamps and plate in the Accessories tab.

Select & Configure Model
Base Model #Body SizeCable lengthShaft Type/SizeProgrammableOutput SignalApprovalsConfigure Part #
 
17251080 mm OD x 66 mm1.5 m · preset 0–60°N/AYes4–20 mA / HARTCE
17253680 mm OD x 66 mm5 mN/AYes4–20 mA / HARTCE
17254480 mm OD x 66 mm10 mN/AYes4–20 mA / HARTCE
17392280 mm OD x 66 mm30 mN/AYes4–20 mA / HARTCE
18160280 mm OD x 66 mm35 mN/AYes4–20 mA / HARTCE
18621480 mm OD x 66 mm40 mN/AYes4–20 mA / HARTCE
18161080 mm OD x 66 mm60 mN/AYes4–20 mA / HARTCE
Measuring Range:

Programmable between 0 - 360°

Sense of rotation:

Adjustable for rotation clockwise or counter-clockwise

Output Signal:

Load-independent DC current,
proportional to the inclination

Weight:

approx. 1.1 kg [35.366 oz]

Housing:

Stainless-steel INOX AiSi 316Ti (1.4571)

Enclosure Rating:

IP68 per EN 60529, 30 m water column

Communication interface:

HART-compatible, two-wire 4–20 mA

Mounting Orientation:

Perpendicular to the object being measured

Dielectric strength:

500 V RMS at 50 Hz for 1 minute

Storage Temperature:

−30 to +70 °C for transport and storage

Vibration:

40 m/s² over 10–500 Hz per EN 60068-2-6

Inclination Angle:

Set to -180 - 179.99°

Power Supply:

8 - 33 VDC

Standard range:

4 - 20 mA, 2-wire connection
protection against wrong polarity

Accuracy:

± 0.2 ° (at +25 °C)

Resolution:

14-bit

Temperature coefficient:

From −30 to +70 °C, 0.1° per 10 K below 100° span and up to 0.2° per 10 K above 100° span.

Current Consumption:

<22 mA. Fault current high >21.5 mA or low <3.5 mA.

EMC-lmmunity influence:

Emissions EN 61000-6-4. Immunity EN 61000-6-2.

Operating Temperature:

−30 to +70 °C

Shock:

300 m/s² for 18 ms per EN 60068-2-27



Mod Tronic Instruments Limited
1 Delta Park Blvd #12
Brampton, ON L6T 5G1
Phone: 905-457-6322 or 1-800-794-5883
Fax: 905-457-4716 or 1-800-830-7122
Brampton
Halifax
Regina
Edmonton
905-457-6322
902-422-0978
306-359-1476
780-459-2690
Montreal
Winnipeg
Calgary
Vancouver
514-848-7205
204-895-2038
403-236-2909
604-224-9547